NF EN ISO 16000-12

NF EN ISO 16000-12

April 2009
Standard Current

Indoor air - Part 12 : sampling strategy for polychlorinated biphenyls (PCBs), polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs) and polycyclic aromatic hydrocarbons (PAHs)

ISO 16000-12:2008 specifies the planning of measurements for polychlorinated biphenyls (PCBs), polychlorinated dibenzo-p-dioxins (PCDDs) also known as polychlorinated oxanthrenes, polychlorinated dibenzofurans (PCDFs) and polycyclic aromatic hydrocarbons (PAHs) in indoor air. In the case of indoor air measurements, the careful planning of sampling and the entire measurement strategy are of particular significance since the result of the measurement may have far-reaching consequences, e.g. with respect to the need for remedial action or the success of such an action.An inappropriate measurement strategy may contribute more overall uncertainty to the measurement result than the measurement procedure itself.

View the extract
Main informations

Collections

National standards and national normative documents

Publication date

April 2009

Number of pages

30 p.

Reference

NF EN ISO 16000-12

ICS Codes

13.040.20   Ambient atmospheres

Classification index

X43-404-12

Print number

1 - 24/03/2009

International kinship

European kinship

EN ISO 16000-12:2008
Sumary
Indoor air - Part 12 : sampling strategy for polychlorinated biphenyls (PCBs), polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs) and polycyclic aromatic hydrocarbons (PAHs)

ISO 16000-12:2008 specifies the planning of measurements for polychlorinated biphenyls (PCBs), polychlorinated dibenzo-p-dioxins (PCDDs) also known as polychlorinated oxanthrenes, polychlorinated dibenzofurans (PCDFs) and polycyclic aromatic hydrocarbons (PAHs) in indoor air. In the case of indoor air measurements, the careful planning of sampling and the entire measurement strategy are of particular significance since the result of the measurement may have far-reaching consequences, e.g. with respect to the need for remedial action or the success of such an action.

An inappropriate measurement strategy may contribute more overall uncertainty to the measurement result than the measurement procedure itself.

Table of contents
  • Avant-propos
    iv
  • Introduction
    vi
  • 1 Domaine d'application
    1
  • 2 Références normatives
    1
  • 3 Sources et occurrence des PCB, des PCDD/PCDF et des HAP
    2
  • 4 Mode opératoire de mesure
    4
  • 5 Programme de mesure
    5
  • Annexe A (informative) Structures, toxicité et calcul des équivalents toxiques
    10
  • Annexe B (informative) Mode opératoire d'étude des sources potentielles de pollution par les PCB à l'intérieur des bâtiments en vue d'une éventuelle rénovation
    14
  • Annexe C (informative) Analyses des PCDD/PCDF à l'intérieur des bâtiments suite à un incendie
    16
  • Bibliographie
    17