NF EN ISO 17511

NF EN ISO 17511

January 2004
Standard Cancelled

In vitro diagnostic medical devices - Measurement of quantities in biological samples - Metrological traceability of values assigned to calibrators and control materials

ISO 17511:2003 specifies how to assure the metrological traceability of values assigned to calibrators and control materials intended to establish or verify trueness of measurement. The calibrators and control materials are those provided by the manufacturers as part of, or to be used together with, in vitro diagnostic medical devices.External quality assessment (survey) samples, with proven commutability, whose values have been assigned by means of internationally agreed reference measurement systems or internationally agreed conventional reference measurement systems fall within the scope of ISO 17511:2003.ISO 17511:2003 is not applicable to control materials that do not have an assigned value and are used only for assessing the precision of a measurement procedure, either its repeatability or reproducibility (precision control materials); control materials intended for intralaboratory quality control purposes and supplied with intervals of suggested acceptable values, each interval obtained by interlaboratory consensus with respect to one specified measurement procedure, and with limiting values that are not metrologically traceable; correlation between results of two measurement procedures at the same metrological level, purporting to measure the same quantity, because such "horizontal" correlation does not provide metrological traceability; calibration derived from correlation between the results of two measurement procedures at different metrological levels, but with quantities having analytes of different characteristics; metrological traceability of routine results to the product calibrator and their relations to any medical discrimination limit; and properties involving nominal scales, i.e. where no magnitude is involved (e.g. identification of blood cells).

View the extract
Main informations

Collections

National standards and national normative documents

Publication date

January 2004

Release date

juin 2024 par NF EN ISO 17511 de 2003

Number of pages

31 p.

Reference

NF EN ISO 17511

ICS Codes

11.100.10   In vitro diagnostic test systems

Classification index

S92-021

Print number

1 - 01/03/2004

International kinship

European kinship

EN ISO 17511:2003
Sumary
In vitro diagnostic medical devices - Measurement of quantities in biological samples - Metrological traceability of values assigned to calibrators and control materials

ISO 17511:2003 specifies how to assure the metrological traceability of values assigned to calibrators and control materials intended to establish or verify trueness of measurement. The calibrators and control materials are those provided by the manufacturers as part of, or to be used together with, in vitro diagnostic medical devices.

External quality assessment (survey) samples, with proven commutability, whose values have been assigned by means of internationally agreed reference measurement systems or internationally agreed conventional reference measurement systems fall within the scope of ISO 17511:2003.

ISO 17511:2003 is not applicable to control materials that do not have an assigned value and are used only for assessing the precision of a measurement procedure, either its repeatability or reproducibility (precision control materials); control materials intended for intralaboratory quality control purposes and supplied with intervals of suggested acceptable values, each interval obtained by interlaboratory consensus with respect to one specified measurement procedure, and with limiting values that are not metrologically traceable; correlation between results of two measurement procedures at the same metrological level, purporting to measure the same quantity, because such "horizontal" correlation does not provide metrological traceability; calibration derived from correlation between the results of two measurement procedures at different metrological levels, but with quantities having analytes of different characteristics; metrological traceability of routine results to the product calibrator and their relations to any medical discrimination limit; and properties involving nominal scales, i.e. where no magnitude is involved (e.g. identification of blood cells).

Standard replaced by (1)
NF EN ISO 17511
June 2021
Standard Current
In vitro diagnostic medical devices - Requirements for establishing metrological traceability of values assigned to calibrators, trueness control materials and human samples

This document specifies technical requirements and documentation necessary to establish metrological traceability of values assigned to calibrators, trueness control materials and human samples for quantities measured by IVD MDs. The human samples are those intended to be measured, as specified for each IVD MD. Metrological traceability of values for quantities in human samples extends to the highest available reference system component, ideally to RMPs and certified reference materials (CRMs). All parties having a role in any of the steps described in a calibration hierarchy for an IVD MD are subject to the requirements described. These parties include but are not limited to manufacturers (of IVD MDs), RMP developers (see ISO 15193), RM producers (see ISO 15194), and reference/calibration laboratories (see ISO 15195) supporting calibration hierarchies for IVD MDs. NOTE 1 Producers of RMs intended for use in standardization or calibration of IVD MDs include commercial and non-commercial organizations producing RMs for use by many end-users of IVD MDs and/or calibration laboratories, or for use by a single end-user medical laboratory, as in the case of a measurement standard (calibrator) intended to be used exclusively for calibration of a laboratory-developed MP. This document is applicable to: a) all IVD MDs that provide measurement results in the form of numeric values, i.e. rational (ratio) and/or differential (interval) scales, and counting scales. b) IVD MDs where the measurement result is reported as a qualitative value established with a ratio of two measurements (i.e. the signal from a specimen being tested and the signal from a RM with a specified concentration or activity at the cut-off), or a counting scale, with corresponding decision threshold(s). This also includes IVD MDs where results are categorized among ordinal categories based on pre-established quantitative intervals for a quantity. c) RMs intended for use as trueness control materials for verification or assessment of calibration of IVD MDs, i.e. some commutable CRMs and some external quality assessment (EQA) materials (if so indicated in the RM's intended use statement). d) IVD MD-specific calibrators and trueness control materials with assigned values, intended to be used together with a specified IVD MD. e) IVD MDs as described in a) and b), where no end-user performed calibration is required (i.e. when the manufacturer performs a factory calibration of the IVD MD). This document is not applicable to: a) calibrators and trueness control materials for IVD MDs which, due to their formulation, are known to have zero amount of measurand; b) control materials that are used only for internal quality control purposes in medical laboratories to assess the imprecision of an IVD MD, either its repeatability or reproducibility, and/or for assessing changes in IVD MD results compared to a previously established calibration condition; c) control materials that are used only for internal quality control purposes in medical laboratories and which are supplied with intervals of suggested acceptable values that are not metrologically traceable to higher order reference system components; d) properties reported as nominal scales and ordinal scales, where no magnitude is involved. NOTE 2 Nominal scales are typically used to report e.g. identity of blood cell types, microorganism types, identity of nucleic acid sequences, identity of urine particles. NOTE 3 Ordinal scales are often applied to results differentiated into dichotomous groupings (e.g. ?sick' vs. ?healthy'), and occasionally to results differentiated into non-dichotomous categories where the result categories are rank-ordered but the rank-ordered categories cannot be differentiated in terms of relative degree of difference, e.g. negative, +1, +2, +3 for grading of presence of haemoglobin in urine specimens by visual observation.

Table of contents
  • Avant-propos
    3
  • Introduction
    4
  • 1 Domaine d'application
    5
  • 2 Références normatives
    6
  • 3 Termes et définitions
    7
  • 4 Chaîne de traçabilité et hiérarchie d'étalonnage
    12
  • 4.1 Principes
    12
  • 4.2 Structure et nomenclature
    13
  • 4.3 Facteurs à prendre en compte pour l'établissement de la traçabilité
    17
  • 4.4 Fonctions des matériaux de référence
    18
  • 5 Protocoles de transfert d'étalonnage
    18
  • 5.1 Disponibilité et structure des protocoles de transfert
    18
  • 5.2 Cas où l'on dispose d'un mode opératoire de mesure de référence primaire et de matériau(x) de référence primaires) avec traçabilité au Système international d'unités
    19
  • 5.3 Cas où l'on dispose d'un mode opératoire de mesure de référence conventionnel international (non primaire) et de matériaux) d'étalonnage conventionnel(s) international (internationaux) sans traçabilité au Système international d'unités
    20
  • 5.4 Cas où l'on dispose d'un mode opératoire de mesure de référence conventionnel international (non primaire) mais sans matériau d'étalonnage conventionnel international ni traçabilité au Système international d'unités
    21
  • 5.5 Cas où l'on dispose d'un matériau d'étalonnage conventionnel international (qui n'est pas primaire) sans mode opératoire de mesure de référence conventionnel international ni traçabilité au Système international d'unités
    22
  • 5.6 Cas où l'on dispose d'un mode opératoire de mesure choisi par le fabricant sans mode opératoire de mesure de référence conventionnel reconnu au niveau international ni matériau d'étalonnage conventionnel international et sans traçabilité au Système international des unités
    23
  • 5.7 Matériaux de contrôle de la justesse
    24
  • 6 Détermination et expression de l'incertitude de mesure
    24
  • 7 Validation d'un étalonnage traçable métrologiquement
    25
  • 8 Informations relatives à la traçabilité à faire figurer dans le mode d'emploi d'un dispositif de diagnostic médical in vitro 26
  • Annexe ZA (informative) Articles de la présente Norme européenne concernant les exigences essentielles ou d'autres dispositions des Directives UE
    27
  • Bibliographie
    28
ZOOM ON ... the Requirements department
To comply with a standard, you need to quickly understand its issues in order to determine its impact on your activity.

The Requirements department helps you quickly locate within the normative text:
- mandatory clauses to satisfy,
- non-essential but useful clauses to know, such as permissions and recommendations.

The identification of these types of clauses is based on the document “ISO / IEC Directives, Part 2 - Principles and rules of structure and drafting of ISO documents ”as well as on a constantly enriched list of verbal forms.

With Requirements, quickly access the main part of the normative text!

With Requirements, quickly access the main part of the normative text!
Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo

I discover COBAZ