NF EN ISO 17852
- Consult online for free
- Consult the entire collection of French and European standards for free in the regional delegations of the AFNOR Group by clicking here
Water quality - Determination of mercury - Method using atomic fluorescence spectrometry
ISO 17852:2006 specifies a method for the determination of mercury in drinking, surface, ground and rain water using atomic fluorescence spectrometry. It may be applied to industrial and municipal waste water after an additional digestion step under appropriate conditions. The potential linear dynamic range is approximately 1 nanogram per litre to 100 micrograms per litre. In practice, the working range is often from 10 nanograms per litre to 10 micrograms per litre.Samples containing mercury at concentrations higher than the working range can be analysed following appropriate dilution of the sample. The method detection limit will be dependent on the selected operating conditions and calibration range. With high purity reagents, a method detection limit of less than 1 nanogram per litre is obtainable.The relative standard deviation is typically less than 5 % for concentrations greater than twenty times the method detection limit. The sensitivity of this method is dependent on the selected operating conditions.
ISO 17852:2006 specifies a method for the determination of mercury in drinking, surface, ground and rain water using atomic fluorescence spectrometry. It may be applied to industrial and municipal waste water after an additional digestion step under appropriate conditions. The potential linear dynamic range is approximately 1 nanogram per litre to 100 micrograms per litre. In practice, the working range is often from 10 nanograms per litre to 10 micrograms per litre.
Samples containing mercury at concentrations higher than the working range can be analysed following appropriate dilution of the sample. The method detection limit will be dependent on the selected operating conditions and calibration range. With high purity reagents, a method detection limit of less than 1 nanogram per litre is obtainable.The relative standard deviation is typically less than 5 % for concentrations greater than twenty times the method detection limit. The sensitivity of this method is dependent on the selected operating conditions.
Le présent document s'adresse aux laboratoires ayant à doser le mercure total dans la plupart des types d'eaux à de faibles concentrations. Il décrit une méthode par spectrométrie de fluorescence atomique après minéralisation au brome.
-
1 Domaine d'application1
-
2 Références normatives1
-
3 Principe2
-
4 Interférences2
-
5 Réactifs et étalons2
-
6 Appareillage et instrumentation5
-
7 Prélèvement et prétraitement des échantillons6
-
8 Réglage des instruments7
-
9 Mode opératoire7
-
10 Rapport d'essai8
-
11 Données de fidélité9
- Annexe A (informative) Informations complémentaires10
- Annexe B (informative) Schéma de fonctionnement11
- Annexe C (informative) Disponibilité des réactifs12
- Annexe D (informative) Données de fidélité13
- Bibliographie14