Acoustics - Characterization of sources of structure-borne sound and vibration - Indirect measurement of blocked forces
This document specifies a method where a vibrating component (a source of structure-borne sound or vibration) is attached to a passive structure (or receiver) and is the cause of vibration in, or structure-borne sound radiation from, the assembly. Examples are pumps installed in ships, servo motors in vehicles or machines and plant in buildings. Almost any vibrating component can be considered as a source in this context.Due to the need to measure vibration at all contact degrees of freedom (DOFs) (connections between the source and receiver), this document can only be applied to assemblies for which such measurement is possible.This document is applicable only to assemblies whose frequency response functions (FRFs) are linear and time invariant.The source can be installed into a real assembly or attached to a specially designed test stand (as described in 5.2).The standard method has been validated for stationary signals such that the results can be presented in the frequency domain. However, the method is not restricted to stationary signals: with appropriate data processing, it is also applicable to time-varying signals such as transients and shocks (provided linearity and time invariance of the FRFs are preserved).This document provides a method for measurement and presentation of blocked forces, together with guidelines for minimizing uncertainty. It provides a method evaluating the quality of the results through an on-board validation procedure but does not comment on the acceptability or otherwise of the results.
This document specifies a method where a vibrating component (a source of structure-borne sound or vibration) is attached to a passive structure (or receiver) and is the cause of vibration in, or structure-borne sound radiation from, the assembly. Examples are pumps installed in ships, servo motors in vehicles or machines and plant in buildings. Almost any vibrating component can be considered as a source in this context.
Due to the need to measure vibration at all contact degrees of freedom (DOFs) (connections between the source and receiver), this document can only be applied to assemblies for which such measurement is possible.
This document is applicable only to assemblies whose frequency response functions (FRFs) are linear and time invariant.
The source can be installed into a real assembly or attached to a specially designed test stand (as described in 5.2).
The standard method has been validated for stationary signals such that the results can be presented in the frequency domain. However, the method is not restricted to stationary signals: with appropriate data processing, it is also applicable to time-varying signals such as transients and shocks (provided linearity and time invariance of the FRFs are preserved).
This document provides a method for measurement and presentation of blocked forces, together with guidelines for minimizing uncertainty. It provides a method evaluating the quality of the results through an on-board validation procedure but does not comment on the acceptability or otherwise of the results.
This document specifies a method where a vibrating component (a source of structure-borne sound or vibration) is attached to a passive structure (or receiver) and is the cause of vibration in, or structure-borne sound radiation from, the assembly. Examples are pumps installed in ships, servo motors in vehicles or machines and plant in buildings. Almost any vibrating component can be considered as a source in this context. Due to the need to measure vibration at all contact degrees of freedom (DOFs) (connections between the source and receiver), this document can only be applied to assemblies for which such measurement is possible. This document is applicable only to assemblies whose frequency response functions (FRFs) are linear and time invariant. The source can be installed into a real assembly or attached to a specially designed test stand (as described in 5.2). The standard method has been validated for stationary signals such that the results can be presented in the frequency domain. However, the method is not restricted to stationary signals: with appropriate data processing, it is also applicable to time-varying signals such as transients and shocks (provided linearity and time invariance of the FRFs are preserved). This document provides a method for measurement and presentation of blocked forces, together with guidelines for minimizing uncertainty. It provides a method evaluating the quality of the results through an on-board validation procedure but does not comment on the acceptability or otherwise of the results.
- Avant-propos
-
1 Domaine d'application
-
2 Références normatives
-
3 Termes et définitions
-
4 Sélection des degrés de liberté (DDL)
-
5 Montage d'essai
-
6 Appareillage de mesure
-
7 Mode opératoire d'essai
-
8 Procédure d'analyse
-
9 Incertitudes et validation
-
10 Rapport d'essai
- Annexe A (informative) Exemple de rapport d'essai: entraînement électrique de l'essieu arrière d'une voiture particulière; analyse des voies de transfert (TPA) et estimation des forces bloquées in situ conformément à l'ISO 20270:2019
- Annexe B (informative) Essais de la validité des données de mesure
- Annexe C (informative) Études de cas
- Annexe D (informative) Critères de sélection des DDL d'indicateur et de validation
- Annexe E (informative) Prévision du bruit et des vibrations
- Bibliographie
The Requirements department helps you quickly locate within the normative text:
- mandatory clauses to satisfy,
- non-essential but useful clauses to know, such as permissions and recommendations.
The identification of these types of clauses is based on the document “ISO / IEC Directives, Part 2 - Principles and rules of structure and drafting of ISO documents ”as well as on a constantly enriched list of verbal forms.
With Requirements, quickly access the main part of the normative text!

At a glance, you will be able to identify the additions, deletions or modifications to a text, table, figure and formula.

The Redlines + service is offered to you on the collection of French standards in force, in French language and in HTML and PDF format.
For an overview of the service, click on View a standard in redline format
COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.
Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!
Request your free, no-obligation live demo
I discover COBAZ