NF EN ISO 22007-2
Plastics - Determination of thermal conductivity and thermal diffusivity - Part 2 : transient plane heat source (hot disk) method
ISO 22007-2:2008 specifies a method for the determination of the thermal conductivity and thermal diffusivity, and hence the specific heat capacity per unit volume, of plastics. The experimental arrangement can be designed to match different specimen sizes. Measurements can be made in gaseous and vacuum environments at a range of temperatures and pressures.This method is suitable for testing homogeneous and isotropic materials, as well as anisotropic materials with a uniaxial structure. In general, the method is suitable for materials having values of thermal conductivity, λ, in the approximate range 0,01 Wm-1K-1 < λ < 500 Wm-1K-1 and values of thermal diffusivity, α, in the range 5 x 10-8 m2s-1 ≤ α ≤ 10-4 m2s-1, and for temperatures, T, in the approximate range 50 K < T < 1 000 K.The thermal-transport properties of liquids can also be determined, provided care is taken to minimize thermal convection.
ISO 22007-2:2008 specifies a method for the determination of the thermal conductivity and thermal diffusivity, and hence the specific heat capacity per unit volume, of plastics. The experimental arrangement can be designed to match different specimen sizes. Measurements can be made in gaseous and vacuum environments at a range of temperatures and pressures.
This method is suitable for testing homogeneous and isotropic materials, as well as anisotropic materials with a uniaxial structure. In general, the method is suitable for materials having values of thermal conductivity, λ, in the approximate range 0,01 Wm-1K-1 < λ < 500 Wm-1K-1 and values of thermal diffusivity, α, in the range 5 x 10-8 m2s-1 ≤ α ≤ 10-4 m2s-1, and for temperatures, T, in the approximate range 50 K < T < 1 000 K.
The thermal-transport properties of liquids can also be determined, provided care is taken to minimize thermal convection.
ISO 22007-2:2015 specifies a method for the determination of the thermal conductivity and thermal diffusivity, and hence the specific heat capacity per unit volume of plastics. The experimental arrangement can be designed to match different specimen sizes. Measurements can be made in gaseous and vacuum environments at a range of temperatures and pressures.
- Avant-proposiv
- Introductionv
-
1 Domaine d'application1
-
2 Références normatives1
-
3 Termes et définitions2
-
4 Principe3
-
5 Appareillage3
-
6 Éprouvette d'essai5
-
6.1 Éprouvettes en masse5
-
6.2 Éprouvettes en masse anisotropes6
-
6.3 Éprouvettes en plaque6
-
6.4 Éprouvettes à pellicules minces7
-
7 Mode opératoire7
-
8 Calcul des propriétés thermiques9
-
8.1 Éprouvettes en masse9
-
8.2 Éprouvettes en masse anisotropes12
-
8.3 Éprouvettes en plaque13
-
8.4 Éprouvettes à pellicules minces14
-
9 Étalonnage et vérification14
-
9.1 Étalonnage de l'appareil14
-
9.2 Vérification de l'appareil15
-
10 Fidélité et biais15
-
11 Rapport d'essai16
- Bibliographie17
- With a single click, add a new language, the Requirements or Redline+ service and add one or more additional users.
- Whether you are in the process of acquiring a standard or it is already available in your personal space, the UPSELL service is available at every stage to help you understand it and implement it within your organization.
COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.
Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!
Request your free, no-obligation live demo
I discover COBAZ