NF EN ISO 389-3

NF EN ISO 389-3

April 2016
Standard Current

Acoustics - Reference zero for the calibration of audiometric equipment - Part 3 : reference equivalent threshold vibratory force levels for pure tones and bone vibrators

ISO 389-1:2016 specifies the following data applicable to the calibration of bone vibrators for pure-tone bone-conduction audiometry: a) reference equivalent threshold vibratory force levels (RETVFL), corresponding to the threshold of hearing of young otologically normal persons by bone-conduction audiometry; b) essential characteristics of the bone vibrator and the method of coupling to the test subject, and to the mechanical coupler; c) essential characteristics of the masking noise and the baseline masking noise level applied to the ear not under test. Guidance on the practical application of this part of ISO 389 in the calibration of audiometers is given in Annex B. RETVFL is the vibratory force level transmitted to a mechanical coupler of specified characteristics by a vibrator when applied to the mechanical coupler under stated conditions of test and when energized at the voltage level corresponding to the normal threshold of hearing for location on the mastoid prominence. NOTE 1 Values for the differences in reference equivalent threshold vibratory force levels between location on the forehead and mastoid are included for information in Annex C. NOTE 2 Recommended procedures for carrying out bone-conduction audiometry are specified in ISO 8253‑1.

View the extract
Main informations

Collections

National standards and national normative documents

Thematics

Gestion des risques et SST, QSE, Sécurité

Publication date

April 2016

Number of pages

21 p.

Reference

NF EN ISO 389-3

ICS Codes

13.140   Noise with respect to human beings

Classification index

S30-007-3

Print number

1

International kinship

European kinship

EN ISO 389-3:2016
Sumary
Acoustics - Reference zero for the calibration of audiometric equipment - Part 3 : reference equivalent threshold vibratory force levels for pure tones and bone vibrators

ISO 389-1:2016 specifies the following data applicable to the calibration of bone vibrators for pure-tone bone-conduction audiometry:

a) reference equivalent threshold vibratory force levels (RETVFL), corresponding to the threshold of hearing of young otologically normal persons by bone-conduction audiometry;

b) essential characteristics of the bone vibrator and the method of coupling to the test subject, and to the mechanical coupler;

c) essential characteristics of the masking noise and the baseline masking noise level applied to the ear not under test.

Guidance on the practical application of this part of ISO 389 in the calibration of audiometers is given in Annex B.

RETVFL is the vibratory force level transmitted to a mechanical coupler of specified characteristics by a vibrator when applied to the mechanical coupler under stated conditions of test and when energized at the voltage level corresponding to the normal threshold of hearing for location on the mastoid prominence.

NOTE 1 Values for the differences in reference equivalent threshold vibratory force levels between location on the forehead and mastoid are included for information in Annex C.

NOTE 2 Recommended procedures for carrying out bone-conduction audiometry are specified in ISO 8253‑1.

Replaced standards (1)
NF EN ISO 389-3
August 1999
Standard Cancelled
Acoustics. Reference zero for the calibration of audiometric equipment. Part 3 : reference equivalent threshold force levels for pure tones and bone vibrators.

Table of contents
View the extract
  • 1 Domaine d'application
  • 2 Références normatives
  • 3 Termes et définitions
  • 4 Niveaux de référence équivalents de force vibratoire liminaire
  • 5 Conditions d'essai et exigences
  • Annexe A Notes concernant l'obtention des niveaux de référence équivalents de force vibratoire liminaire
  • Annexe B Préconisations concernant l'utilisation du zéro de référence pour l'étalonnage des audiomètres en conduction osseuse
  • Annexe C Différences de niveau de référence équivalent de force vibratoire liminaire entre l'emplacement sur le front et l'emplacement sur l'apophyse mastoïde du vibrateur
  • Annexe D Seuils d'audition en conduction osseuse pour les fréquences inférieures à 250 Hz
  • Bibliographie
ZOOM ON ... the Requirements department
To comply with a standard, you need to quickly understand its issues in order to determine its impact on your activity.

The Requirements department helps you quickly locate within the normative text:
- mandatory clauses to satisfy,
- non-essential but useful clauses to know, such as permissions and recommendations.

The identification of these types of clauses is based on the document “ISO / IEC Directives, Part 2 - Principles and rules of structure and drafting of ISO documents ”as well as on a constantly enriched list of verbal forms.

With Requirements, quickly access the main part of the normative text!

With Requirements, quickly access the main part of the normative text!
What is the Redline format?
The Redline + service - standards comparator allows you to easily and simply identify major changes between the current standard and its last canceled version.

At a glance, you will be able to identify the additions, deletions or modifications to a text, table, figure and formula.
At a glance, you will be able to identify the additions, deletions or modifications to a text, table, figure and formula

The Redlines + service is offered to you on the collection of French standards in force, in French language and in HTML and PDF format.

For an overview of the service, click on View a standard in redline format
Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo

I discover COBAZ