Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 1 : general principles and requirements

ISO 5167-1:2003 defines terms and symbols and establishes the general principles for methods of measurement and computation of the flowrate of fluid flowing in a conduit by means of pressure differential devices (orifice plates, nozzles and Venturi tubes) when they are inserted into a circular cross-section conduit running full. ISO 5167-1:2003 also specifies the general requirements for methods of measurement, installation and determination of the uncertainty of the measurement of flowrate. It also defines the general specified limits of pipe size and Reynolds number for which these pressure differential devices are to be used.ISO 5167 (all parts) is applicable only to flow that remains subsonic throughout the measuring section and where the fluid can be considered as single-phase. It is not applicable to the measurement of pulsating flow.

Main informations

Collections

National standards and national normative documents

Publication date

June 2003

Number of pages

41 p.

Reference

NF EN ISO 5167-1

ICS Codes

17.120.10   Flow in closed conduits

Classification index

X10-102-1

Print number

1 - 07/08/2003

International kinship

European kinship

EN ISO 5167-1:2003
Sumary
Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 1 : general principles and requirements

ISO 5167-1:2003 defines terms and symbols and establishes the general principles for methods of measurement and computation of the flowrate of fluid flowing in a conduit by means of pressure differential devices (orifice plates, nozzles and Venturi tubes) when they are inserted into a circular cross-section conduit running full.

ISO 5167-1:2003 also specifies the general requirements for methods of measurement, installation and determination of the uncertainty of the measurement of flowrate. It also defines the general specified limits of pipe size and Reynolds number for which these pressure differential devices are to be used.

ISO 5167 (all parts) is applicable only to flow that remains subsonic throughout the measuring section and where the fluid can be considered as single-phase. It is not applicable to the measurement of pulsating flow.

Replaced standards (2)
NF EN ISO 5167-1
November 1995
Standard Cancelled
Measurement of fluid flow by means of pressure differential devices. Part 1 : orifice plates, nozzles and venturi tubes inserted in circular cross-section conduits running full.

NF EN ISO 5167-1/A1
October 1998
Standard Cancelled
Mesure de débit des fluides au moyen d'appareils déprimogènes - Partie 1 : diaphragmes, tuyères et tubes de venturi insérés dans des conduites en charge de section circulaire

Ce premier amendement à la norme ISO 5167-1:1991, permet un calcul amélioré du coefficient de décharge C. En outre, ce coefficient peut désormais être appliqué pour des nombres de Reynolds rapportés au diamètre de la conduite inférieures à 4 000 d'une part et d'autre part le rapport de diamètre beta = d/D doit être toujours supérieur ou égal à 0,10 et inférieur ou égal à 0,75.

Standard replaced by (1)
NF EN ISO 5167-1
June 2022
Standard Current
Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 1: General principles and requirements

This document defines terms and symbols and establishes the general principles for methods of measurement and computation of the flow rate of fluid flowing in a conduit by means of pressure differential devices (orifice plates, nozzles, Venturi tubes, cone meters, and wedge meters) when they are inserted into a circular cross-section conduit running full. This document also specifies the general requirements for methods of measurement, installation and determination of the uncertainty of the measurement of flow rate. ISO 5167 (all parts) is applicable only to flow that remains subsonic throughout the measuring section and where the fluid can be considered as single-phase. It is not applicable to the measurement of pulsating flow.

ZOOM ON ... the Requirements department
To comply with a standard, you need to quickly understand its issues in order to determine its impact on your activity.

The Requirements department helps you quickly locate within the normative text:
- mandatory clauses to satisfy,
- non-essential but useful clauses to know, such as permissions and recommendations.

The identification of these types of clauses is based on the document “ISO / IEC Directives, Part 2 - Principles and rules of structure and drafting of ISO documents ”as well as on a constantly enriched list of verbal forms.

With Requirements, quickly access the main part of the normative text!

With Requirements, quickly access the main part of the normative text!
New: UPSELL service
- The UPSELL service allows you to easily update one of your standards.
- With a single click, add a new language, the Requirements or Redline+ service and add one or more additional users.
- Whether you are in the process of acquiring a standard or it is already available in your personal space, the UPSELL service is available at every stage to help you understand it and implement it within your organization.
Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo

I discover COBAZ