NF EN ISO 7396-1/A2

NF EN ISO 7396-1/A2

April 2010
Standard Cancelled

Medical gas pipeline systems - Part 1 : pipeline systems for compressed medical gases and vacuum - Amendment 2

Le présent amendement remplace le paragraphe 5.5.1.3 pour exclure toute utilisation d'air médical et d'air moteur susceptible de nuire à la disponibilité et à la qualité de l'air.

View the extract
Main informations

Collections

National standards and national normative documents

Publication date

April 2010

Number of pages

11 p.

Reference

NF EN ISO 7396-1/A2

ICS Codes

11.040.10   Anaesthetic, respiratory and reanimation equipment

Classification index

S95-155/A2

Print number

1 - 25/03/2010

International kinship

European kinship

EN ISO 7396-1/A2:2010
Sumary
Medical gas pipeline systems - Part 1 : pipeline systems for compressed medical gases and vacuum - Amendment 2

Le présent amendement remplace le paragraphe 5.5.1.3 pour exclure toute utilisation d'air médical et d'air moteur susceptible de nuire à la disponibilité et à la qualité de l'air.
Standard replaced by (1)
NF EN ISO 7396-1
May 2016
Standard Current
Medical gas pipeline systems - Part 1 : pipeline systems for compressed medical gases and vacuum

<p>ISO 7396-1:2016 specifies requirements for design, installation, function, performance, testing, commissioning and documentation of pipeline systems used in healthcare facilities for the following:</p> <p>- oxygen;</p> <p>- nitrous oxide;</p> <p>- medical air;</p> <p>- carbon dioxide;</p> <p>- oxygen/nitrous oxide mixtures (see Note 1);</p> <p>- helium/oxygen mixtures;</p> <p>- (*) oxygen 93;</p> <p>- gases and gas mixtures classified as medical device, gases delivered to medical devices or intended for medical purposes or gases and gas mixtures for medicinal use not specified above;</p> <p>- air for driving surgical tools;</p> <p>- nitrogen for driving surgical tools;</p> <p>- vacuum.</p> <p>NOTE 1 Regional or national regulations may prohibit the distribution of oxygen/nitrous oxide mixtures in medical gas pipeline systems.</p> <p>NOTE 2 Anaesthetic gas scavenging disposal systems are covered in ISO 7396‑2.</p> <p>This part of ISO 7396 includes requirements for supply systems, pipeline distribution systems, control systems, monitoring and alarm systems and non-interchangeability between components of different gas/vacuum systems.</p> <p>This part of ISO 7396 specifies safety requirements for pipeline systems used in healthcare facilities, both public and private. It applies to all facilities providing healthcare services regardless of type, size, location or range of services, including, but not limited to:</p> <p>a) acute care healthcare facilities;</p> <p>b) internal patient continuing care healthcare facilities;</p> <p>c) long-term care facilities;</p> <p>d) community-based providers;</p> <p>e) ambulatory and external patient care clinics (e.g. day surgery, endoscopy clinics and doctors' offices).</p> <p>NOTE 3 This part of ISO 7396 may also be used as reference for pipeline systems for medical gases and vacuum intended to be installed in places other than healthcare facilities.</p> <p>ISO 7396-1:2016 applies to the following different types of oxygen supply systems:</p> <p>- supply systems in which all sources of supply deliver oxygen; in this case the concentration of the oxygen will be greater than 99%;</p> <p>- supply systems in which all sources of supply deliver oxygen 93; in this case the concentration of the oxygen may vary between 90% and 96%;</p> <p>NOTE 4 A mixture of oxygen 93 and oxygen may be delivered by a medical gas supply system. In this case the concentration of the gas can vary between 90% and &gt;99%.</p> <p>ISO 7396-1:2016 also applies to:</p> <p>- extensions of existing pipeline distribution systems;</p> <p>- modifications of existing pipeline distribution systems;</p> <p>- modifications or replacement of supply systems or sources of supply.</p> <p>Oxygen concentrators for domiciliary use are excluded from the scope of this part of ISO 7396.</p> <p>NOTE 5 Requirements for oxygen concentrators for domiciliary use are specified in ISO 80601‑2-69.</p> <p>(*) EN 14931 defines additional requirements for hyperbaric application, in particular for flows and pressures of compressed air required to pressurize the hyperbaric chamber and to drive other connected services. Also included are requirements for oxygen and other treatment gases administered to patients.</p> <p>ISO 7396-1:2016 does not apply to vacuum systems intended to be used in dentistry.</p> <p>ISO 7396-1:2016 does not apply to filling systems for transportable cylinders and transportable cylinder bundle systems.</p>

ZOOM ON ... the Requirements department
To comply with a standard, you need to quickly understand its issues in order to determine its impact on your activity.

The Requirements department helps you quickly locate within the normative text:
- mandatory clauses to satisfy,
- non-essential but useful clauses to know, such as permissions and recommendations.

The identification of these types of clauses is based on the document “ISO / IEC Directives, Part 2 - Principles and rules of structure and drafting of ISO documents ”as well as on a constantly enriched list of verbal forms.

With Requirements, quickly access the main part of the normative text!

With Requirements, quickly access the main part of the normative text!
Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo

I discover COBAZ