NF EN ISO 80369-7

July 2017
Standard Cancelled

Small-bore connectors for liquids and gases in healthcare applications - Part 7 : connectors for intravascular or hypodermic applications

ISO 80369-7:2016 specifies dimensions and requirements for the design and functional performance of small-bore connectors intended to be used for connections in intravascular applications or hypodermic connections in hypodermic applications of medical devices and accessories.EXAMPLES Hypodermic syringes and needles or intravascular (IV) cannulae with male and female luer slip connectors and luer lock connectors.NOTE 1 The luer connector was originally designed for use at pressures up to 300 kPa.ISO 80369-7:2016 does not specify requirements for the medical devices or accessories that use these connectors. Such requirements are given in particular International Standards for specific medical devices or accessories.ISO 80369-7:2016 does not specify requirements for the following small-bore connectors, which are specified in other International Standards:- haemodialyser, haemodiafilter and haemofilter blood compartment ports (ISO 8637 and applicable portion of ISO 8638 referencing blood compartment ports);- haemodialysis, haemodiafiltration and haemofiltration equipment connectors (ISO 8637);- infusion system closure piercing connectors (ISO 8536‑4).NOTE 2 Manufacturers are encouraged to incorporate the small-bore connectors specified in this part of ISO 80369 into medical devices or accessories, even if currently not required by the relevant particular medical device standards. It is expected that when the relevant particular medical device standards are revised, requirements for small-bore connectors, as specified in ISO 80369, will be included.NOTE 3 ISO 80369‑1:2010, 5.8, specifies alternative methods of compliance with ISO 80369‑1:2010, for small-bore connectors intended for use with intravascular applications or hypodermic application medical devices or accessories, which do not comply with this part of ISO 80369.

View the extract
Main informations

Collections

National standards and national normative documents

Publication date

July 2017

Number of pages

55 p.

Reference

NF EN ISO 80369-7

ICS Codes

11.040.25   Syringes, needles and catheters

Classification index

S97-190-7

Print number

1

International kinship

European kinship

EN ISO 80369-7:2017
Sumary
Small-bore connectors for liquids and gases in healthcare applications - Part 7 : connectors for intravascular or hypodermic applications

ISO 80369-7:2016 specifies dimensions and requirements for the design and functional performance of small-bore connectors intended to be used for connections in intravascular applications or hypodermic connections in hypodermic applications of medical devices and accessories.

EXAMPLES Hypodermic syringes and needles or intravascular (IV) cannulae with male and female luer slip connectors and luer lock connectors.

NOTE 1 The luer connector was originally designed for use at pressures up to 300 kPa.

ISO 80369-7:2016 does not specify requirements for the medical devices or accessories that use these connectors. Such requirements are given in particular International Standards for specific medical devices or accessories.

ISO 80369-7:2016 does not specify requirements for the following small-bore connectors, which are specified in other International Standards:

- haemodialyser, haemodiafilter and haemofilter blood compartment ports (ISO 8637 and applicable portion of ISO 8638 referencing blood compartment ports);

- haemodialysis, haemodiafiltration and haemofiltration equipment connectors (ISO 8637);

- infusion system closure piercing connectors (ISO 8536‑4).

NOTE 2 Manufacturers are encouraged to incorporate the small-bore connectors specified in this part of ISO 80369 into medical devices or accessories, even if currently not required by the relevant particular medical device standards. It is expected that when the relevant particular medical device standards are revised, requirements for small-bore connectors, as specified in ISO 80369, will be included.

NOTE 3 ISO 80369‑1:2010, 5.8, specifies alternative methods of compliance with ISO 80369‑1:2010, for small-bore connectors intended for use with intravascular applications or hypodermic application medical devices or accessories, which do not comply with this part of ISO 80369.

Replaced standards (3)
NF EN 20594-1
December 1993
Standard Cancelled
Conical fittings with a 6 per cent (luer) taper for syringes, needles and certain other medical equipment. Part 1 : general requirements.

NF EN 20594-1/A1
July 1998
Standard Cancelled
Conical fittings with a 6% (Luer) taper for syringes, needles and certain other medical equipment - Part 1: General requirements

Le présent document complète la norme de base qui vient à l'appui des exigences essentielles de la Directive de l'Union européenne 93/42/CEE.

NF EN 1707
February 1997
Standard Cancelled
Conical fittings with a 6 % (LUER) taper for syringes, needles and certain other medical equipment. Lock fittings.

Le présent document établit les exigences des assemblages coniques à verrouillage, réalisés dans des matériaux rigides ou semi-rigides, avec un cône de 6 % (Luer) adaptés aux seringues et aiguilles hypodermiques, et à d'autres équipements à usage médical.

Standard replaced by (1)
Standard Current
Small-bore connectors for liquids and gases in healthcare applications - Part 7 : Connectors for intravascular or hypodermic applications

This document specifies dimensions and requirements for the design and functional performance of small-bore connectors intended to be used for connections in intravascular applications or hypodermic connections in hypodermic applications of medical devices and accessories. EXAMPLES Hypodermic syringes and needles or intravascular (IV) cannulae with male and female Luer slip connectors and Luer lock connectors. NOTE 1 See Annex A. NOTE 2 The Luer connector was originally designed for use at pressures up to 300 kPa. This document does not specify requirements for themedical devices or accessories that use these connectors. Such requirements are given in particular documents for specific medical devices or accessories. This document does not specify requirements for the following small-bore connectors, which are specified in other documents: - haemodialyser, haemodiafilter and haemofilter blood compartment ports (ISO 8637 [5] and applicable portion of ISO 8638 [ 6] referencing blood compartment ports); - haemodialysis, haemodiafiltration and haemofiltration equipment connectors (ISO 8637 [5]); - infusion system closure piercing connectors (ISO 8536-4 [4]). NOTE 3 Manufacturers are encouraged to incorporate thesmall-bore connectors specified in this document into medical devices or accessories, even if currently not required by the relevant particular medical device documents. It is expected that when the relevant particular medical device documents are revised, requirements for small-bore connectors, as specified in ISO 80369, will be included. NOTE 4 ISO 80369-1:2018, Clause 7, specifies alternative methods of conformance with ISO 80369-1:2018, for small-bore connectors intended for use with intravascular applications or hypodermic application medical devices or accessories, which do not conform with this document.

Table of contents
  • 1 * Domaine d'application
  • 2 Références normatives
  • 3 Termes et définitions
  • 4 Exigences générales
  • 5 * Exigences dimensionnelles relatives aux raccords Luer
  • 6 Exigences de performance
  • Annexe A Exposé des motifs et préconisations
  • Annexe B Raccords Luer
  • Annexe C Raccords de référence
  • Annexe D Évaluation des dispositifs médicaux présentant des raccordements entrant dans le cadre de cette application et de leurs propriétés
  • Annexe E Récapitulatif des exigences d'aptitude à l'utilisation des raccords Luer destinés à des applications intravasculaires ou hypodermiques
  • Annexe F Récapitulatif des exigences de conception des raccords Luer destinés à des applications intravasculaires ou hypodermiques
  • Annexe G Récapitulatif de l'évaluation du modèle du raccord Luer destiné à des applications intravasculaires ou hypodermiques
  • Annexe H Référence aux principes essentiels
  • Annexe I Terminologie - Index alphabétique des termes définis
  • Bibliographie
Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo

I discover COBAZ