NF EN ISO 8434-1
Metallic tube connections for fluid power and general use - Part 1 : 24 degree cone connectors
This document specifies the general and dimensional requirements for 24° cone connectors using cutting ring and O‑ring seal cone (referred to as DKO) suitable for use with ferrous and non‑ferrous tubes with outside diameters from 4 mm to 42 mm inclusive. These connectors are for use in fluid power and general applications within the limits of pressure and temperature specified in this document.They are intended for the connection of plain end tubes and hose fittings to ports in accordance with ISO 6149‑1, ISO 1179‑1 and ISO 9974‑1. (See ISO 12151‑2 for a related hose fitting specification.)These connectors provide full-flow connections in hydraulic systems operating to the working pressures shown in Table 1. Because many factors influence the pressure at which a system performs satisfactorily, these values are not intended to be understood as guaranteed minimums. For every application, sufficient testing is meant to be conducted and reviewed by both the user and manufacturer to ensure that required performance levels are met.NOTE 1 For new designs in hydraulic fluid power applications, see the requirements given in 9.6. Where the requirements of the application allow for the use of elastomeric seals, connector designs that conform to International Standards and incorporate elastomeric sealing are preferred.NOTE 2 For use under conditions outside the pressure and/or temperature limits specified, see 5.4.This document also specifies a performance and qualification test for these connectors.
This document specifies the general and dimensional requirements for 24° cone connectors using cutting ring and O‑ring seal cone (referred to as DKO) suitable for use with ferrous and non‑ferrous tubes with outside diameters from 4 mm to 42 mm inclusive. These connectors are for use in fluid power and general applications within the limits of pressure and temperature specified in this document.
They are intended for the connection of plain end tubes and hose fittings to ports in accordance with ISO 6149‑1, ISO 1179‑1 and ISO 9974‑1. (See ISO 12151‑2 for a related hose fitting specification.)
These connectors provide full-flow connections in hydraulic systems operating to the working pressures shown in Table 1. Because many factors influence the pressure at which a system performs satisfactorily, these values are not intended to be understood as guaranteed minimums. For every application, sufficient testing is meant to be conducted and reviewed by both the user and manufacturer to ensure that required performance levels are met.
NOTE 1 For new designs in hydraulic fluid power applications, see the requirements given in 9.6. Where the requirements of the application allow for the use of elastomeric seals, connector designs that conform to International Standards and incorporate elastomeric sealing are preferred.
NOTE 2 For use under conditions outside the pressure and/or temperature limits specified, see 5.4.
This document also specifies a performance and qualification test for these connectors.
ISO 8434-1:2007 specifies the general and dimensional requirements for 24° cone connectors using cutting ring and O‑ring seal cone (referred to as DKO) suitable for use with ferrous and non‑ferrous tubes with outside diameters from 4 mm to 42 mm inclusive. These connectors are for use in fluid power and general applications within the limits of pressure and temperature specified in ISO 8434-1:2007. It also specifies a performance and qualification test for these connectors.
- Avant-propos
-
1 Domaine d'application
-
2 Références normatives
-
3 Termes et définitions
-
4 Matériaux
-
5 Exigences de pression/de température
-
6 Désignation des raccords
-
7 Exigences pour les tubes
-
8 Dimensions et tolérances des cotes surplats
-
9 Conception
-
10 Filetages
-
11 Fabrication
-
12 Instructions de montage
-
13 Informations relatives à l'achat
-
14 Marquage des composants
-
15 Essai de performance
-
16 Phrase d'identification (référence au présent document)
- Annexe A (normative) Instructions de montage des raccords coniques à 24° à l'aide d'une bague coupante conformément à l'ISO 8434-1
- Bibliographie
The Requirements department helps you quickly locate within the normative text:
- mandatory clauses to satisfy,
- non-essential but useful clauses to know, such as permissions and recommendations.
The identification of these types of clauses is based on the document “ISO / IEC Directives, Part 2 - Principles and rules of structure and drafting of ISO documents ”as well as on a constantly enriched list of verbal forms.
With Requirements, quickly access the main part of the normative text!

At a glance, you will be able to identify the additions, deletions or modifications to a text, table, figure and formula.

The Redlines + service is offered to you on the collection of French standards in force, in French language and in HTML and PDF format.
For an overview of the service, click on View a standard in redline format
COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.
Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!
Request your free, no-obligation live demo
I discover COBAZ