NF EN ISO 9698
Water quality - Determination of tritium activity concentration - Liquid scintillation counting method
ISO 9698:2010 specifies the conditions for the determination of tritium activity concentration in samples of environmental water or of tritiated water using liquid scintillation counting.The choice of the analytical procedure, either with or without distillation of the water sample prior to determination, depends on the aim of the measurement and the sample characteristics.Direct measurement of a raw water sample using liquid scintillation counting has to consider the potential presence of other beta emitter radionuclides. To avoid interference with these radionuclides when they are detected, the quantification of tritium will be performed following the sample treatment by distillation. Three distillation procedures are described.The method is not applicable to the analysis of organically bound tritium; its determination requires additional chemical processing (such as chemical oxidation or combustion).With suitable technical conditions, the detection limit may be as low as 1 Bq l-1. Tritium activity concentrations below 106 Bq l-1 can be determined without any sample dilution. A prior enrichment step can significantly lower the limit of detection.
ISO 9698:2010 specifies the conditions for the determination of tritium activity concentration in samples of environmental water or of tritiated water using liquid scintillation counting.
The choice of the analytical procedure, either with or without distillation of the water sample prior to determination, depends on the aim of the measurement and the sample characteristics.
Direct measurement of a raw water sample using liquid scintillation counting has to consider the potential presence of other beta emitter radionuclides. To avoid interference with these radionuclides when they are detected, the quantification of tritium will be performed following the sample treatment by distillation. Three distillation procedures are described.
The method is not applicable to the analysis of organically bound tritium; its determination requires additional chemical processing (such as chemical oxidation or combustion).
With suitable technical conditions, the detection limit may be as low as 1 Bq l-1. Tritium activity concentrations below 106 Bq l-1 can be determined without any sample dilution. A prior enrichment step can significantly lower the limit of detection.
ISO 9698:2010 specifies the conditions for the determination of tritium activity concentration in samples of environmental water or of tritiated water using liquid scintillation counting. The choice of the analytical procedure, either with or without distillation of the water sample prior to determination, depends on the aim of the measurement and the sample characteristics. Direct measurement of a raw water sample using liquid scintillation counting has to consider the potential presence of other beta emitter radionuclides. To avoid interference with these radionuclides when they are detected, the quantification of tritium will be performed following the sample treatment by distillation. Three distillation procedures are described. The method is not applicable to the analysis of organically bound tritium; its determination requires additional chemical processing (such as chemical oxidation or combustion). With suitable technical conditions, the detection limit may be as low as 1 Bq l-1. Tritium activity concentrations below 106 Bq l-1 can be determined without any sample dilution. A prior enrichment step can significantly lower the limit of detection.
This document specifies a method by liquid scintillation counting for the determination of tritium activity concentration in samples of marine waters, surface waters, ground waters, rain waters, drinking waters or of tritiated water ([3H]H2O) in effluents. The method is not directly applicable to the analysis of organically bound tritium; its determination requires additional chemical processing of the sample (such as chemical oxidation or combustion). With suitable technical conditions, the detection limit may be as low as 1 Bq·l−1. Tritium activity concentrations below 106 Bq·l−1 can be determined without any sample dilution.
-
1 Domaine d'application
-
2 Références normatives
-
3 Symboles, définitions et unités
-
4 Principe
-
5 Réactifs et équipement
-
6 Échantillonnage et échantillons
-
7 Mode opératoire
-
8 Expression des résultats
-
9 Rapport d'essai
- Annexe A Applications numériques
- Annexe B Distillation d'échantillons de volume important
- Annexe C Méthode avec solution d'étalon interne
- Annexe D Distillation d'échantillons de faible volume
- Annexe E Méthode d'évaluation pour matrices humides
- Bibliographie
The Requirements department helps you quickly locate within the normative text:
- mandatory clauses to satisfy,
- non-essential but useful clauses to know, such as permissions and recommendations.
The identification of these types of clauses is based on the document “ISO / IEC Directives, Part 2 - Principles and rules of structure and drafting of ISO documents ”as well as on a constantly enriched list of verbal forms.
With Requirements, quickly access the main part of the normative text!

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.
Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!
Request your free, no-obligation live demo
I discover COBAZ