NF ISO 10816-2

NF ISO 10816-2

April 2010
Standard Cancelled

Mechanical vibration - Evaluation of machine vibration by measurements on non-rotating parts - Part 2 : land-based steam turbines and generators in excess of 50 MW with normal operating speeds of 1 500 r/min, 1 800 r/min, 3 000 r/min and 3 600 r/min

ISO 10816-2:2009 establishes provisions for evaluating the severity of in-situ, broad-band vibration measured radial (i.e. transverse) to the shaft axis on all main bearing housings or pedestals and in the axial direction on thrust bearings. These are in terms of: - vibration under normal steady-state operating conditions; - vibration during other (non-steady-state) conditions when transient changes are taking place, including run up or run down, initial loading and load changes; - changes in vibration which can occur during normal steady-state operation. ISO 10816-2:2009 is applicable to land-based steam turbines and generators with power outputs greater than 50 MW and a normal operating speed of 1 500 r/min, 1 800 r/min, 3 000 r/min or 3 600 r/min.

View the extract
Main informations

Collections

National standards and national normative documents

Publication date

April 2010

Number of pages

22 p.

Reference

NF ISO 10816-2

ICS Codes

17.160   Vibrations, shock and vibration measurements
27.040   Gas and steam turbines. Steam engines
29.160.40   Generating sets

Classification index

E90-760-2

Print number

1 - 31/03/2010

International kinship

Sumary
Mechanical vibration - Evaluation of machine vibration by measurements on non-rotating parts - Part 2 : land-based steam turbines and generators in excess of 50 MW with normal operating speeds of 1 500 r/min, 1 800 r/min, 3 000 r/min and 3 600 r/min

ISO 10816-2:2009 establishes provisions for evaluating the severity of in-situ, broad-band vibration measured radial (i.e. transverse) to the shaft axis on all main bearing housings or pedestals and in the axial direction on thrust bearings. These are in terms of:

- vibration under normal steady-state operating conditions;

- vibration during other (non-steady-state) conditions when transient changes are taking place, including run up or run down, initial loading and load changes;

- changes in vibration which can occur during normal steady-state operation.

ISO 10816-2:2009 is applicable to land-based steam turbines and generators with power outputs greater than 50 MW and a normal operating speed of 1 500 r/min, 1 800 r/min, 3 000 r/min or 3 600 r/min.

Standard replaced by (1)
NF ISO 20816-2
October 2017
Standard Current
Mechanical vibration - Measurement and evaluation of machine vibration - Part 2 : Land-based gas turbines, steam turbines and generators in excess of 40 MW, with fluid-film bearings and rated speeds of 1 500 r/min, 1 800 r/min, 3 000 r/min and 3 600 r/min

<p>ISO 20816-2:2017 is applicable to land-based gas turbines, steam turbines and generators (whether coupled with gas and/or steam turbines) with power outputs greater than 40 MW, fluid-film bearings and rated speeds of 1 500 r/min, 1 800 r/min, 3 000 r/min or 3 600 r/min. The criteria provided in ISO 20816-2:2017 can be applied to the vibration of the gas turbine, steam turbine and generator (including synchronizing clutches). ISO 20816-2:2017 establishes provisions for evaluating the severity of the following <i>in-situ</i>, broad-band vibration:</p> <p>a) structural vibration at all main bearing housings or pedestals measured radial (i.e. transverse) to the shaft axis;</p> <p>b) structural vibration at thrust bearing housings measured in the axial direction;</p> <p>c) vibration of rotating shafts radial (i.e. transverse) to the shaft axis at, or close to, the main bearings.</p> <p>These are in terms of the following:</p> <p>- vibration under normal steady-state operating conditions;</p> <p>- vibration during other (non-steady-state) conditions when transient changes are taking place, including run up or run down, initial loading and load changes;</p> <p>- changes in vibration which can occur during normal steady-state operation.</p> <p>ISO 20816-2:2017 is not applicable to the following:</p> <p>i) electromagnetic excited vibration with twice line frequency at the generator stator windings, core and housing;</p> <p>ii) aero-derivative gas turbines (including gas turbines with dynamic properties similar to those of aero-derivatives);</p> <p>NOTE ISO 3977‑3 defines aero-derivatives as aircraft propulsion gas generators adapted to drive mechanical, electrical or marine propulsion equipment. Large differences exist between heavy-duty and aero-derivative gas turbines, for example, in casing flexibility, bearing design, rotor-to-stator mass ratio and mounting structure. Different criteria, therefore, apply for these two turbine types.</p> <p>iii) steam turbines and/or generators with outputs less than or equal to 40 MW or with rated speeds other than 1 500 r/min, 1 800 r/min, 3 000 r/min or 3 600 r/min (although generators seldom fall into this latter category) (see ISO 7919‑3 and ISO 10816‑3);</p> <p>iv) gas turbines with outputs less than or equal to 40 MW or with rated speeds other than 1 500 r/min, 1 800 r/min, 3 000 r/min or 3 600 r/min (see ISO 7919‑3 or ISO 7919‑4 and ISO 10816‑3 or ISO 10816‑4);</p> <p>v) the evaluation of combustion vibration but does not preclude monitoring of combustion vibration.</p>

Table of contents
View the extract
  • Avant-propos
    iv
  • Introduction
    VI
  • 1 Domaine d'application
    1
  • 2 Références normatives
    1
  • 3 Modes opératoires de mesurage
    2
  • 4 Critères d'évaluation
    4
  • 4.1 Généralités
    4
  • 4.2 Critère I: Amplitude des vibrations
    4
  • 4.3 Critère II: Variation de l'amplitude des vibrations dans des conditions de régime permanent à une vitesse de fonctionnement normale
    10
  • 4.4 Modes opératoires/critères supplémentaires
    11
  • 4.5 Évaluation fondée sur les informations relatives aux vecteurs de vibrations
    11
  • Annexe A (normative) Limites des zones d'évaluation
    12
  • Annexe B (informative) Exemple de positionnement des valeurs d'ALARME et de DÉCLENCHEMENT
    13
  • Annexe C (normative) Notes de mise en garde relatives à l'utilisation des critères de vitesse de vibrations aux vitesses de rotation basses
    14
  • Bibliographie
    16
Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo