NF ISO 11476

NF ISO 11476

October 2010
Standard Cancelled

Paper and board - Determination of CIE-whiteness, C/2° (indoor illumination conditions)

ISO 11476:2010 specifies the procedure to be used for determining the CIE whiteness of papers and boards, in order to obtain values which correspond to the visual appearance of white papers and boards, with or without fluorescent whitening agents, when they are viewed indoors. It is based on radiance factor data obtained over the full visible spectral range (VIS) in contrast to the measurement of ISO brightness, which is limited to the blue region of VIS. ISO 11476:2010 also specifies the procedures for the determination of CIE tint values and the fluorescent component of CIE whiteness. In addition, it specifies a method for adjustment of the UV content to correspond to that of CIE illuminant C, since the results obtained when fluorescent whitening agents are present are dependent upon the UV content of the radiation falling upon the sample. The CIE illuminant C is taken to be representative of indoor illumination conditions because it contains a suitable proportion of UV radiation. This method is not applicable to coloured papers containing fluorescent dyes. It is specific to the situation where the fluorescence occurs in the blue region of the visible spectral range. ISO 11476:2010 is read in conjunction with ISO 2469.

View the extract
Main informations

Collections

National standards and national normative documents

Publication date

October 2010

Number of pages

17 p.

Reference

NF ISO 11476

ICS Codes

85.060   Paper and board

Classification index

Q03-105

Print number

1 - 24/09/2010

International kinship

Sumary
Paper and board - Determination of CIE-whiteness, C/2° (indoor illumination conditions)

ISO 11476:2010 specifies the procedure to be used for determining the CIE whiteness of papers and boards, in order to obtain values which correspond to the visual appearance of white papers and boards, with or without fluorescent whitening agents, when they are viewed indoors. It is based on radiance factor data obtained over the full visible spectral range (VIS) in contrast to the measurement of ISO brightness, which is limited to the blue region of VIS. ISO 11476:2010 also specifies the procedures for the determination of CIE tint values and the fluorescent component of CIE whiteness.

In addition, it specifies a method for adjustment of the UV content to correspond to that of CIE illuminant C, since the results obtained when fluorescent whitening agents are present are dependent upon the UV content of the radiation falling upon the sample. The CIE illuminant C is taken to be representative of indoor illumination conditions because it contains a suitable proportion of UV radiation. This method is not applicable to coloured papers containing fluorescent dyes. It is specific to the situation where the fluorescence occurs in the blue region of the visible spectral range.

ISO 11476:2010 is read in conjunction with ISO 2469.

Standard replaced by (1)
NF ISO 11476
October 2016
Standard Current
Paper and board - Determination of CIE whiteness, C/2° (indoor illumination conditions)

<p>ISO 11476:2016 specifies the procedure to be used for determining the CIE whiteness of papers and boards, in order to obtain values which correspond to the visual appearance of white papers and boards, with or without fluorescent whitening agents, when they are viewed indoors. It is based on radiance factor data obtained over the full visible spectral range (VIS) in contrast to the measurement of ISO brightness, which is limited to the blue region of VIS. It also specifies the procedures for the determination of CIE tint values and the fluorescent component of CIE whiteness.</p> <p>In addition, it specifies a method for adjustment of the UV-content to correspond to that of CIE illuminant C,[10][12] since the results obtained when fluorescent whitening agents are present are dependent upon the UV-content of the radiation falling upon the sample. The CIE illuminant C is taken to be representative of indoor illumination conditions because it contains a suitable proportion of UV radiation.[7] This method is not applicable to coloured papers containing fluorescent dyes. It is specific to the situation where the fluorescence occurs in the blue region of the visible spectral range.</p> <p>ISO 11476:2016 is read in conjunction with ISO 2469.</p>

Table of contents
View the extract
  • Avant-propos
    iv
  • 1 Domaine d'application
    1
  • 2 Références normatives
    1
  • 3 Termes et définitions
    2
  • 4 Principe
    3
  • 5 Appareillage et équipement
    3
  • 6 Étalonnage
    4
  • 7 Échantillonnage et conditionnement
    5
  • 8 Préparation des éprouvettes
    5
  • 9 Mode opératoire
    5
  • 10 Calcul et expression des résultats
    6
  • 11 Fidélité
    7
  • 12 Rapport d'essai
    7
  • Annexe A (normative) Caractéristiques spectrales des réflectomètres pour la détermination des composantes trichromatiques
    8
  • Annexe B (normative) Service d'étalonnage UV
    11
  • Bibliographie
    13
Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo

I discover COBAZ