NF ISO 230-6

NF ISO 230-6

October 2003
Standard Current

Test code for machines tools - Part 6 : determination of positioning accuracy on body and face diagonals (Digital displacement tests)

This part of ISO 230 specifies diagonal displacement tests which allow the estimation of the volumetric performance of a machine tool. Complete testing of the volumetric performance of a machine tool is a difficult and time-consuming process. Diagonal displacement tests reduce the time and cost associated with testing the volumetric performance. A diagonal displacement test is not in itself a diagnostic test, although conclusions of a diagnostic nature may sometimes be possible from the results. In particular, when face diagonal tests are included, a direct measurement of the axes squareness is possible. Diagonal displacement tests on body diagonals may be supplemented by tests in the face diagonals, by tests parallel to the machine axes in accordance with ISO 230-2, or by the evaluation of the contouring performance in the three coordinate planes as defined in ISO 230-4. Diagonal displacement tests may be used for acceptance purposes and as reassurance of machine performance where parameters of the test are used as comparison index.

View the extract
Main informations

Collections

National standards and national normative documents

Publication date

October 2003

Number of pages

13 p.

Reference

NF ISO 230-6

ICS Codes

25.080.01   Machine tools in general

Classification index

E60-145

Print number

1 - 01/12/2003

International kinship

Sumary
Test code for machines tools - Part 6 : determination of positioning accuracy on body and face diagonals (Digital displacement tests)

This part of ISO 230 specifies diagonal displacement tests which allow the estimation of the volumetric performance of a machine tool. Complete testing of the volumetric performance of a machine tool is a difficult and time-consuming process. Diagonal displacement tests reduce the time and cost associated with testing the volumetric performance.

A diagonal displacement test is not in itself a diagnostic test, although conclusions of a diagnostic nature may sometimes be possible from the results. In particular, when face diagonal tests are included, a direct measurement of the axes squareness is possible. Diagonal displacement tests on body diagonals may be supplemented by tests in the face diagonals, by tests parallel to the machine axes in accordance with ISO 230-2, or by the evaluation of the contouring performance in the three coordinate planes as defined in ISO 230-4.

Diagonal displacement tests may be used for acceptance purposes and as reassurance of machine performance where parameters of the test are used as comparison index.