NF ISO 4037-2

NF ISO 4037-2

July 2000
Standard Cancelled

X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy - Part 2 : dosimetry for radiation protection over the energy ranges 8 keV to 1,3 MeV and 4 MeV to 9 MeV

View the extract
Main informations

Collections

National standards and national normative documents

Publication date

July 2000

Number of pages

36 p.

Reference

NF ISO 4037-2

ICS Codes

17.240   Radiation measurements

Classification index

M60-512-2

Print number

1 - 08/06/2006

International kinship

Replaced standards (2)
NF M60-512
October 1984
Standard Cancelled
X and gamma reference radiations for calibrating dosemeters and dose ratemeters and for determining their response as a function of photon energy.

NF ISO 4037/AD2
March 1990
Standard Cancelled
X and gamma reference radiations for calibrating dosemeters and dose ratemeters and for determining their response as a function of photon energy. Photon reference radiations at energies between 4 mev and 9 mev.

La présente norme, qui complète la norme NF M 60-512 d'octobre 1984, donne les spécifications des rayonnements de photons de référence dans le domaine d'énergie compris entre 4 MeV et 9 MeV destinés à l'étalonnage des dosimètres et débitmètres utilisés en radioprotection et à la détermination de leur réponse en fonction de l'énergie. Elle concerne les méthodes de production des rayonnements de photons de référence et donne les principales contaminations des rayonnements de référence, produits par les méthodes spécifiées afin d'évaluer l'influence des contaminations sur les valeurs mesurées par les dosimètres et les débitmètres à étalonner.

Standard replaced by (1)
NF ISO 4037-2
June 2019
Standard Cancelled
Radiological protection - X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy - Part 2 : dosimetry for radiation protection over the energy ranges from 8 keV to 1,3 MeV and 4 MeV to 9 MeV

This document specifies the procedures for the dosimetry of X and gamma reference radiation for the calibration of radiation protection instruments over the energy range from approximately 8 keV to 1,3 MeV and from 4 MeV to 9 MeV and for air kerma rates above 1 µGy/h. The considered measuring quantities are the air kerma free-in-air, Ka, and the phantom related operational quantities of the International Commission on Radiation Units and Measurements (ICRU)[2], H*(10), Hp(10), H'(3), Hp(3), H'(0,07) and Hp(0,07), together with the respective dose rates. The methods of production are given in ISO 4037-1. This document can also be used for the radiation qualities specified in ISO 4037-1:2019, Annexes A, B and C, but this does not mean that a calibration certificate for radiation qualities described in these annexes is in conformity with the requirements of ISO 4037. The requirements and methods given in this document are targeted at an overall uncertainty (k = 2) of the dose(rate) of about 6 % to 10 % for the phantom related operational quantities in the reference fields. To achieve this, two production methods of the reference fields are proposed in ISO 4037-1. The first is to produce "matched reference fields", which follow the requirements so closely that recommended conversion coefficients can be used. The existence of only a small difference in the spectral distribution of the "matched reference field" compared to the nominal reference field is validated by procedures, which are given and described in detail in this document. For matched reference radiation fields, recommended conversion coefficients are given in ISO 4037-3 only for specified distances between source and dosemeter, e.g., 1,0 m and 2,5 m. For other distances, the user has to decide if these conversion coefficients can be used. The second method is to produce "characterized reference fields". Either this is done by determining the conversion coefficients using spectrometry, or the required value is measured directly using secondary standard dosimeters. This method applies to any radiation quality, for any measuring quantity and, if applicable, for any phantom and angle of radiation incidence. The conversion coefficients can be determined for any distance, provided the air kerma rate is not below 1 µGy/h. Both methods require charged particle equilibrium for the reference field. However this is not always established in the workplace field for which the dosemeter shall be calibrated. This is especially true at photon energies without inherent charged particle equilibrium at the reference depth d, which depends on the actual combination of energy and reference depth d. Electrons of energies above 65 keV, 0,75 MeV and 2,1 MeV can just penetrate 0,07 mm, 3 mm and 10 mm of ICRU tissue, respectively, and the radiation qualities with photon energies above these values are considered as radiation qualities without inherent charged particle equilibrium for the quantities defined at these depths. This document is not applicable for the dosimetry of pulsed reference fields.

Table of contents
  • 1 Domaine d'application
    1
  • 2 Références normatives
    1
  • 3 Définitions
    2
  • 4 Appareillage
    4
  • 5 Procédures générales
    4
  • 6 Procédures applicables aux chambres d'ionisation
    6
  • 7 Procédures additionnelles et précautions particulières à la dosimétrie des rayonnements gamma de sources radioactives
    9
  • 8 Procédures additionnelles et précautions spécifiques de la dosimétrie des rayonnements X
    9
  • 9 Procédures spéciales et précautions spécifiques pour les rayonnements X de fluorescence - Limitation du rayonnement parasite
    12
  • 10 Dosimétrie des rayonnements de référence de photons d'énergie comprise entre 4 MeV et 9 MeV
    12
  • 11 Incertitudes affectant les mesures
    24
  • Annexe A (informative) Détermination du kerma dans l'air en l'absence de récepteur et de la dose absorbée dans les tissus (ou dans l'eau) en présence de récepteur à l'aide d'une chambre d'ionisation
    26
  • Annexe B (informative) Bibliographie
    29
ZOOM ON ... the Requirements department
To comply with a standard, you need to quickly understand its issues in order to determine its impact on your activity.

The Requirements department helps you quickly locate within the normative text:
- mandatory clauses to satisfy,
- non-essential but useful clauses to know, such as permissions and recommendations.

The identification of these types of clauses is based on the document “ISO / IEC Directives, Part 2 - Principles and rules of structure and drafting of ISO documents ”as well as on a constantly enriched list of verbal forms.

With Requirements, quickly access the main part of the normative text!

With Requirements, quickly access the main part of the normative text!
Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo

I discover COBAZ