NF ISO 4548-12
Methods of test for full-flow lubricating oil filters for internal combustion engines - Part 12 : filtration efficiency using particle counting and contaminant retention capacity
ISO 4548-12:2017 specifies a multi-pass filtration test with continuous contaminant injection and using the online particle counting method for evaluating the performance of full-flow lubricating oil filters for internal combustion engines. The scope of this document is limited to steady state conditions and does not address fluctuations in the flow rate.The test procedure determines the contaminant capacity of a filter, its particulate removal characteristics and differential pressure.This test is intended for application to filter elements with an efficiency of less than 99 % at particle size greater than 10 μm.NOTE Several test flow loops built into one test rig, or several test rigs, would be necessary to cover the complete flow range of 2 l/min to 600 l/min.
ISO 4548-12:2017 specifies a multi-pass filtration test with continuous contaminant injection and using the online particle counting method for evaluating the performance of full-flow lubricating oil filters for internal combustion engines. The scope of this document is limited to steady state conditions and does not address fluctuations in the flow rate.
The test procedure determines the contaminant capacity of a filter, its particulate removal characteristics and differential pressure.
This test is intended for application to filter elements with an efficiency of less than 99 % at particle size greater than 10 μm.
NOTE Several test flow loops built into one test rig, or several test rigs, would be necessary to cover the complete flow range of 2 l/min to 600 l/min.
-
1 Domaine d'application
-
2 Références normatives
-
3 Termes et définitions
-
4 Symboles
-
5 Équipement et matériaux d'essai
-
6 Précision des instruments de mesure et conditions d'essai
-
7 Validation du banc d'essai
-
8 Préparation
-
9 Mode opératoire
-
10 Calculs et consignation des résultats des essais
- Annexe A Spécifications du fluide utilisé pour l'essai du filtre à huile 1 Des fluides d'essai appropriés sont les huiles hydrauliques d'aviation MIL-H-5606 et AIR 3520.
- Annexe B Rapport type d'essai du filtre
- Annexe C Calcul de l'efficacité du filtre
- Annexe D Essai interlaboratoires
- Bibliographie
To comply with a standard, you need to quickly understand its issues in order to determine its impact on your activity.
The Requirements department helps you quickly locate within the normative text:
- mandatory clauses to satisfy,
- non-essential but useful clauses to know, such as permissions and recommendations.
The identification of these types of clauses is based on the document "ISO/IEC Directives, Part 2 - Principles and rules of structure and drafting of ISO documents" as well as on a constantly enriched list of verbal forms.
With Requirements, quickly access the main part of the normative text!

- The UPSELL service allows you to easily update one of your standards.
- With a single click, add a new language, the Requirements or Redline+ service and add one or more additional users.
- Whether you are in the process of acquiring a standard or it is already available in your personal space, the UPSELL service is available at every stage to help you understand it and implement it within your organization.
COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.
Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!
Request your free, no-obligation live demo
I discover COBAZ