NF ISO 8769
NF ISO 8769

NF ISO 8769

March 2021
Standard Cancelled

Measurement of radioactivity — Alpha-, beta- and photon emitting radionuclides — Reference measurement standard specifications for the calibration of surface contamination monitors

Le présent document spécifie les caractéristiques d''étalons de référence de contamination de surface radioactive, traçables par rapport à des étalons nationaux de mesurage, permettant l''étalonnage des contrôleurs de contamination de surface. Le présent document se rapporte aux émetteurs alpha, aux émetteurs bêta et aux émetteurs de photons dont l''énergie photonique maximale est inférieure ou égale à 1,5 MeV.

Main informations

Collections

National standards and national normative documents

Publication date

March 2021

Number of pages

22 p.

Reference

NF ISO 8769

ICS Codes

17.240   Radiation measurements

Print number

1
Sumary
Measurement of radioactivity — Alpha-, beta- and photon emitting radionuclides — Reference measurement standard specifications for the calibration of surface contamination monitors

Le présent document spécifie les caractéristiques d''étalons de référence de contamination de surface radioactive, traçables par rapport à des étalons nationaux de mesurage, permettant l''étalonnage des contrôleurs de contamination de surface. Le présent document se rapporte aux émetteurs alpha, aux émetteurs bêta et aux émetteurs de photons dont l''énergie photonique maximale est inférieure ou égale à 1,5 MeV.
Replaced standards (1)
NF ISO 8769
NF ISO 8769
March 2016
Standard Cancelled
Reference sources - Calibration of surface contamination monitors - Alpha-, beta- and photon emitters

ISO 8769:2016 specifies the characteristics of reference sources of radioactive surface contamination, traceable to national measurement standards, for the calibration of surface contamination monitors. This International Standard relates to alpha-emitters, beta-emitters, and photon emitters of maximum photon energy not greater than 1,5 MeV. It does not describe the procedures involved in the use of these reference sources for the calibration of surface contamination monitors. Such procedures are specified in IEC 60325[8], IEC 62363[9], and other documents. NOTE Since some of the proposed photon sources include filters, the photon sources are to be regarded as sources of photons of a particular energy range and not as sources of a particular radionuclide. For example, a 241Am source with the recommended filtration does not emit from the surface the alpha particles or characteristic low-energy L X-ray photons associated with the decay of the nuclide. It is designed to be a source that emits photons with an average energy of approximately 60 keV. ISO 8769:2016 also specifies preferred reference radiations for the calibration of surface contamination monitors. These reference radiations are realized in the form of adequately characterized large area sources specified, without exception, in terms of surface emission rates which are traceable to national standards.

Standard replaced by (1)
NF EN ISO 8769
NF EN ISO 8769
December 2022
Standard Current
Measurement of radioactivity - Alpha-, beta- and photon emitting radionuclides - Reference measurement standard specifications for the calibration of surface contamination monitors

ZOOM ON ... the Requirements department

To comply with a standard, you need to quickly understand its issues in order to determine its impact on your activity.

The Requirements department helps you quickly locate within the normative text:

  • mandatory clauses to satisfy,
  • non-essential but useful clauses to know, such as permissions and recommendations.

The identification of these types of clauses is based on the document "ISO/IEC Directives, Part 2 - Principles and rules of structure and drafting of ISO documents" as well as on a constantly enriched list of verbal forms.

With Requirements, quickly access the main part of the normative text!


What is the Redline format?
New: UPSELL service
Need to identify, monitor and decipher standards?