NF EN ISO 19238

NF EN ISO 19238

December 2017
Standard Cancelled

Radiological protection - Performance criteria for service laboratories performing biological dosimetry by cytogenetics

ISO 19238:2014 provides criteria for quality assurance and quality control, evaluation of the performance, and the accreditation of biological dosimetry by cytogenetic service laboratories.ISO 19238:2014 addressesa) the confidentiality of personal information, for the customer and the service laboratory,b) the laboratory safety requirements,c) the calibration sources and calibration dose ranges useful for establishing the reference dose-effect curves that contribute to the dose estimation from chromosome aberration frequency and the minimum resolvable doses,d) the scoring procedure for unstable chromosome aberrations used for biological dosimetry,e) the criteria for converting a measured aberration frequency into an estimate of absorbed dose,f) the reporting of results,g) the quality assurance and quality control,h) informative annexes containing sample instructions for customer, sample questionnaire, sample of report, fitting of the low dose-response curve by the method of maximum likelihood and calculating the error of dose estimate, odds ratio method for cases of suspected exposure to a low dose, and sample data sheet for recording aberrations.

View the extract
Main informations

Collections

National standards and national normative documents

Thematics

Sécurité, Gestion des risques et SST, QSE

Publication date

December 2017

Number of pages

39 p.

Reference

NF EN ISO 19238

ICS Codes

13.280   Radiation protection
17.240   Radiation measurements

Classification index

M60-220

Print number

1

International kinship

European kinship

EN ISO 19238:2017
Sumary
Radiological protection - Performance criteria for service laboratories performing biological dosimetry by cytogenetics

ISO 19238:2014 provides criteria for quality assurance and quality control, evaluation of the performance, and the accreditation of biological dosimetry by cytogenetic service laboratories.

ISO 19238:2014 addresses

a) the confidentiality of personal information, for the customer and the service laboratory,

b) the laboratory safety requirements,

c) the calibration sources and calibration dose ranges useful for establishing the reference dose-effect curves that contribute to the dose estimation from chromosome aberration frequency and the minimum resolvable doses,

d) the scoring procedure for unstable chromosome aberrations used for biological dosimetry,

e) the criteria for converting a measured aberration frequency into an estimate of absorbed dose,

f) the reporting of results,

g) the quality assurance and quality control,

h) informative annexes containing sample instructions for customer, sample questionnaire, sample of report, fitting of the low dose-response curve by the method of maximum likelihood and calculating the error of dose estimate, odds ratio method for cases of suspected exposure to a low dose, and sample data sheet for recording aberrations.

Replaced standards (1)
NF ISO 19238
April 2014
Standard Cancelled
Radiation protection - Performance criteria for service laboratories performing biological dosimetry by cytogenetics

ISO 19238:2014 provides criteria for quality assurance and quality control, evaluation of the performance, and the accreditation of biological dosimetry by cytogenetic service laboratories. ISO 19238:2014 addresses a) the confidentiality of personal information, for the customer and the service laboratory, b) the laboratory safety requirements, c) the calibration sources and calibration dose ranges useful for establishing the reference dose-effect curves that contribute to the dose estimation from chromosome aberration frequency and the minimum resolvable doses, d) the scoring procedure for unstable chromosome aberrations used for biological dosimetry, e) the criteria for converting a measured aberration frequency into an estimate of absorbed dose, f) the reporting of results, g) the quality assurance and quality control, h) informative annexes containing sample instructions for customer, sample questionnaire, sample of report, fitting of the low dose-response curve by the method of maximum likelihood and calculating the error of dose estimate, odds ratio method for cases of suspected exposure to a low dose, and sample data sheet for recording aberrations.

Standard replaced by (1)
NF EN ISO 19238
September 2023
Standard Current
Radiological protection - Performance criteria for service laboratories performing biological dosimetry by cytogenetics - Dicentric assay

This document provides criteria for quality assurance and quality control, evaluation of the performance and the accreditation of biological dosimetry by cytogenetic service laboratories using the dicentric assay performed with manual scoring. This document is applicable to a)    the confidentiality of personal information, for the requestor and the service laboratory, b)    the laboratory safety requirements, c)    the calibration sources and calibration dose ranges useful for establishing the reference dose-response curves that contribute to the dose estimation from unstable chromosome aberration frequency and the detection limit, d)    the scoring procedure for unstable chromosome aberrations used for biological dosimetry, e)    the criteria for converting a measured aberration frequency into an estimate of absorbed dose, f)     the reporting of results, g)    the quality assurance and quality control, and h)    informative annexes containing sample instructions for requestor (see Annex A), sample questionnaire (see Annex B), sample report (see Annex C), fitting of the low dose-response curve by the method of maximum likelihood and calculating the error of the dose estimate (see Annex D), odds ratio method for cases of suspected exposure to a low dose (see Annex E), a method for determining the decision threshold and detection limit (see Annex F) and sample data sheet for recording aberrations (see Annex G).

Table of contents
  • 1 Domaine d'application
  • 2 Termes et définitions
  • 3 Dénombrement des dicentriques
  • 4 Responsabilité du demandeur
  • 5 Responsabilité du laboratoire de service
  • 6 Confidentialité des informations personnelles
  • 7 Exigences de sécurité du laboratoire
  • 8 Courbe (s) de calibration
  • 9 Dénombrement des aberrations chromosomiques instables
  • 10 Critères pour convertir une fréquence d'aberration mesurée en une estimation de dose absorbée
  • 11 Présentation des résultats
  • 12 Assurance de la qualité et contrôle de la qualité
  • Annexe A Instructions pour le demandeur
  • Annexe B Exemple de questionnaire
  • Annexe C Exemple de rapport
  • Annexe D Ajustement de la courbe dose-réponse à un rayonnement de faible TLE par la méthode du maximum de vraisemblance et calcul de l'erreur d'estimation de dose
  • Annexe E Méthode du rapport des odds pour les cas d'exposition suspectée à une faible dose de rayonnements ionisants
  • Annexe F Tableau type pour le dénombrement des aberrations chromosomiques
  • Bibliographie
ZOOM ON ... the Requirements department
To comply with a standard, you need to quickly understand its issues in order to determine its impact on your activity.

The Requirements department helps you quickly locate within the normative text:
- mandatory clauses to satisfy,
- non-essential but useful clauses to know, such as permissions and recommendations.

The identification of these types of clauses is based on the document “ISO / IEC Directives, Part 2 - Principles and rules of structure and drafting of ISO documents ”as well as on a constantly enriched list of verbal forms.

With Requirements, quickly access the main part of the normative text!

With Requirements, quickly access the main part of the normative text!
Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo

I discover COBAZ