Acoustics - Requirements for the performance and calibration of reference sound sources used for the determination of sound power levels

ISO 6926:2016 specifies the acoustical performance requirements for reference sound sources: - temporal steadiness (stability) of the sound power output; - spectral characteristics; - directivity. Temporal steadiness is defined in terms of the standard deviation of repeatability (see 5.2). The spectral characteristics can be verified in either a hemi-anechoic room or a reverberation test room from measurements of the frequency band sound power levels in accordance with this International Standard (see 5.4). The performance requirements on directivity index can only be verified in a hemi-anechoic room (see 5.5.) ISO 6926:2016 also specifies procedures for providing level calibration data and uncertainty on a sound source intended for use as a reference sound source in terms of its sound power level under reference meteorological conditions as defined in Clause 4 in octave and in one-third-octave bands, and with frequency weighting A. ISO 6926:2016 is titled as a calibration standard even though the method is conducted in a testing laboratory and the level calibration results are not directly traceable to national standards of measure in a strict metrological sense. Testing laboratories performing this method are not expected to meet all requirements normally associated with a calibration laboratory. NOTE ISO/IEC 17025[15] specifies different requirements for the competence of testing laboratories and calibration laboratories respectively. Laboratories testing reference sound sources in accordance with this International Standard would typically comply with the requirements for testing laboratories but not necessarily with those for calibration laboratories. ISO 6926:2016 specifies methods to calibrate reference sound sources not only in a free field over a reflecting plane but also in reverberation test rooms at different distances from the boundary surfaces. For the position of the reference sound source on one reflecting plane, the two different test environments mentioned above are considered equivalent for frequency bands above or equal to 200 Hz. At 160 Hz and below, some systematic differences can occur (see 11.2). For frequencies below 100 Hz, an alternative calibration method using sound intensity is given. The sound source can either be placed directly on the floor or mounted on a stand to be used at a certain elevation above the floor. According to this International Standard, stand-mounted sources are calibrated in reverberation test rooms. Floor-mounted sources are either calibrated in hemi-anechoic or in reverberation test rooms. For floor-mounted sources in hemi-anechoic rooms, this International Standard is valid only for sources whose maximum vertical dimension is less than 0,5 m and whose maximum horizontal dimension is less than 0,8 m. According to this International Standard, only floor-mounted reference sound sources can be used when carrying out measurements on a measurement surface. For reference sound sources to be used or calibrated under reverberant conditions, no such restrictions on maximum dimensions apply.

View the extract
Main informations

Collections

National standards and national normative documents

Publication date

April 2016

Number of pages

28 p.

Reference

NF EN ISO 6926

ICS Codes

17.140.01   Acoustic measurements and noise abatement in general

Classification index

S31-692

Print number

1

International kinship

European kinship

EN ISO 6926:2016
Sumary
Acoustics - Requirements for the performance and calibration of reference sound sources used for the determination of sound power levels

ISO 6926:2016 specifies the acoustical performance requirements for reference sound sources:

- temporal steadiness (stability) of the sound power output;

- spectral characteristics;

- directivity.

Temporal steadiness is defined in terms of the standard deviation of repeatability (see 5.2). The spectral characteristics can be verified in either a hemi-anechoic room or a reverberation test room from measurements of the frequency band sound power levels in accordance with this International Standard (see 5.4). The performance requirements on directivity index can only be verified in a hemi-anechoic room (see 5.5.)

ISO 6926:2016 also specifies procedures for providing level calibration data and uncertainty on a sound source intended for use as a reference sound source in terms of its sound power level under reference meteorological conditions as defined in Clause 4 in octave and in one-third-octave bands, and with frequency weighting A.

ISO 6926:2016 is titled as a calibration standard even though the method is conducted in a testing laboratory and the level calibration results are not directly traceable to national standards of measure in a strict metrological sense. Testing laboratories performing this method are not expected to meet all requirements normally associated with a calibration laboratory.

NOTE ISO/IEC 17025[15] specifies different requirements for the competence of testing laboratories and calibration laboratories respectively. Laboratories testing reference sound sources in accordance with this International Standard would typically comply with the requirements for testing laboratories but not necessarily with those for calibration laboratories.

ISO 6926:2016 specifies methods to calibrate reference sound sources not only in a free field over a reflecting plane but also in reverberation test rooms at different distances from the boundary surfaces. For the position of the reference sound source on one reflecting plane, the two different test environments mentioned above are considered equivalent for frequency bands above or equal to 200 Hz. At 160 Hz and below, some systematic differences can occur (see 11.2). For frequencies below 100 Hz, an alternative calibration method using sound intensity is given.

The sound source can either be placed directly on the floor or mounted on a stand to be used at a certain elevation above the floor. According to this International Standard, stand-mounted sources are calibrated in reverberation test rooms. Floor-mounted sources are either calibrated in hemi-anechoic or in reverberation test rooms. For floor-mounted sources in hemi-anechoic rooms, this International Standard is valid only for sources whose maximum vertical dimension is less than 0,5 m and whose maximum horizontal dimension is less than 0,8 m. According to this International Standard, only floor-mounted reference sound sources can be used when carrying out measurements on a measurement surface. For reference sound sources to be used or calibrated under reverberant conditions, no such restrictions on maximum dimensions apply.

Replaced standards (1)
NF EN ISO 6926
October 2001
Standard Cancelled
Acoustics - Requirements for the performance and calibration of reference sound sources for the determination of sound power levels

<p> La présente Norme internationale spécifie les exigences relatives aux performances acoustiques des sources sonores de référence : - stabilité dans le temps et répétabilité de la puissance acoustique émise ; - caractéristiques spectrales ; - indice de directivité. La stabilité de la puissance acoustique émise ainsi que l'indice de directivité, pour les sources pour lesquelles une directivité est requise, sont en général déterminés en liaison avec le diagramme de rayonnement de la source sonore de référence. À cause du mesurage de la directivité (pour les exceptions, voir 5.5), l'évaluation du diagramme de rayonnement ne peut se faire qu'en salle semi-anéchoïque. Pour les mesurages destinés à une vérification régulière, seuls les niveaux de puissance acoustique par bandes de fréquence sont en général déterminés. Dans ce cas, les mesurages peuvent être effectués dans des conditions semi-anéchoïques ou réverbérantes. </p>

Table of contents
View the extract
  • 1 Domaine d'application
  • 2 Références normatives
  • 3 Termes et définitions
  • 4 Conditions météorologiques de référence
  • 5 Exigences de performance
  • 6 Appareillage
  • 7 Installation et fonctionnement de la source sonore de référence pendant l'étalonnage
  • 8 Mode opératoire d'étalonnage en salle semi-anéchoïque
  • 9 Mode opératoire d'étalonnage en salles d'essai réverbérantes
  • 10 Mode opératoire de remplacement pour l'étalonnage aux basses fréquences
  • 11 Incertitude de mesure
  • 12 Informations à consigner
  • 13 Informations à fournir dans le rapport d'essai
  • Annexe A Guide de détermination de C2
  • Annexe B Mode opératoire de remplacement pour l'étalonnage aux basses fréquences
  • Bibliographie
ZOOM ON ... the Requirements department
To comply with a standard, you need to quickly understand its issues in order to determine its impact on your activity.

The Requirements department helps you quickly locate within the normative text:
- mandatory clauses to satisfy,
- non-essential but useful clauses to know, such as permissions and recommendations.

The identification of these types of clauses is based on the document “ISO / IEC Directives, Part 2 - Principles and rules of structure and drafting of ISO documents ”as well as on a constantly enriched list of verbal forms.

With Requirements, quickly access the main part of the normative text!

With Requirements, quickly access the main part of the normative text!
What is the Redline format?
The Redline + service - standards comparator allows you to easily and simply identify major changes between the current standard and its last canceled version.

At a glance, you will be able to identify the additions, deletions or modifications to a text, table, figure and formula.
At a glance, you will be able to identify the additions, deletions or modifications to a text, table, figure and formula

The Redlines + service is offered to you on the collection of French standards in force, in French language and in HTML and PDF format.

For an overview of the service, click on View a standard in redline format
Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo

I discover COBAZ