NF ISO 11338-1
Stationary source emissions - Determination of gas and particle-phase polycyclic aromatic hydrocarbons - Part 1 : sampling
ISO 11338-1:2003 describes methods for the determination of the mass concentration of polycyclic aromatic hydrocarbons (PAHs) in flue gas emissions from stationary sources such as aluminium smelters, coke works, waste incinerators, power stations, and industrial and domestic combustion appliances. ISO 11338-1:2003 describes three sampling methods, which are here regarded as of equivalent value, and specifies the minimum requirements for effective PAH sampling. The three sampling methods are the dilution method (A), the heated filter/condenser/adsorber method (B) and the cooled probe/adsorber method (C). All three methods are based on representative isokinetic sampling, as the PAHs are commonly associated with particles in flue gas. Information is provided to assist in the choice of the appropriate sampling method for the measurement application under consideration. ISO 11338-1:2003 is not applicable to the sampling of fugitive releases of PAHs. NOTE Methods for sample preparation, clean-up and analysis are described in ISO 11338-2 and are intended to be combined with one of the sampling methods described in ISO 11338-1 to complete the whole measurement procedure.
ISO 11338-1:2003 describes methods for the determination of the mass concentration of polycyclic aromatic hydrocarbons (PAHs) in flue gas emissions from stationary sources such as aluminium smelters, coke works, waste incinerators, power stations, and industrial and domestic combustion appliances.
ISO 11338-1:2003 describes three sampling methods, which are here regarded as of equivalent value, and specifies the minimum requirements for effective PAH sampling. The three sampling methods are the dilution method (A), the heated filter/condenser/adsorber method (B) and the cooled probe/adsorber method (C). All three methods are based on representative isokinetic sampling, as the PAHs are commonly associated with particles in flue gas.
Information is provided to assist in the choice of the appropriate sampling method for the measurement application under consideration.
ISO 11338-1:2003 is not applicable to the sampling of fugitive releases of PAHs.
NOTE Methods for sample preparation, clean-up and analysis are described in ISO 11338-2 and are intended to be combined with one of the sampling methods described in ISO 11338-1 to complete the whole measurement procedure.
- Avant-proposiv
- Introductionv
-
1 Domaine d'application1
-
2 Références normatives1
-
3 Termes et définitions1
-
4 Principes et exigences minimales pour les trois méthodes d'échantillonnage2
-
4.1 Principes2
-
4.2 Exigences minimales générales applicables à l'ensemble des méthodes d'échantillonnage2
-
4.3 Préparations d'ordre général et échantillonnage3
-
5 Méthode A - Méthode de dilution4
-
5.1 Principe4
-
5.2 Exigences minimales5
-
5.3 Préparation et échantillonnage5
-
6 Méthode B - Méthode de filtre/condenseur/adsorbant (avec chauffage)7
-
6.1 Principe7
-
6.2 Exigences minimales8
-
6.3 Préparation et échantillonnage8
-
7 Méthode C - Méthode de sondage/adsorption avec refroidissement10
-
7.1 Principe10
-
7.2 Exigences minimales10
-
7.3 Préparation et échantillonnage10
- Annexe A (informative) Applicabilité des méthodes d'échantillonnage13
- Annexe B (informative) Représentations schématiques, dimensions et matériaux de certains dispositifs d'échantillonnage soumis à l'essai15
- Bibliographie26