Industrial fans - Determination of fan sound power levels under standardized laboratory conditions - Part 3 : enveloping surface methods
ISO 13347-3:2004 applies to industrial fans as defined in ISO 5801 and ISO 13349. It is limited to the determination of airborne sound emission for the specified set-ups. Vibration is not measured, nor is the sensitivity of airborne sound emission to vibration effects determined.The sizes of fan which can be tested in accordance with ISO 13347-3:2004 are limited only by the practical aspects of the test set-up. Dimensional limitations, test fan dimensions, and air performance will control the room size, power and mounting requirements for the test fan.The test arrangements in ISO 13347-3:2004 establish the laboratory conditions necessary for a successful test. Rarely will it be possible to meet these requirements in situ and ISO 13347-3:2004 is not intended for field measurements. Intending users are reminded that, in these situations, there may well be additional acoustic system effects where inlet and outlet conditions at the fan are less than ideal.The enveloping surface methods may be used for the determination of open inlet and/or open outlet sound power level of fans for standardized installation types.An estimation (with increased uncertainty) of ducted sound power for fans too small, or otherwise inconvenient, for testing by the in-duct method described in ISO 5136 may also be obtained by the addition of end reflection corrections.
ISO 13347-3:2004 applies to industrial fans as defined in ISO 5801 and ISO 13349. It is limited to the determination of airborne sound emission for the specified set-ups. Vibration is not measured, nor is the sensitivity of airborne sound emission to vibration effects determined.
The sizes of fan which can be tested in accordance with ISO 13347-3:2004 are limited only by the practical aspects of the test set-up. Dimensional limitations, test fan dimensions, and air performance will control the room size, power and mounting requirements for the test fan.
The test arrangements in ISO 13347-3:2004 establish the laboratory conditions necessary for a successful test. Rarely will it be possible to meet these requirements in situ and ISO 13347-3:2004 is not intended for field measurements. Intending users are reminded that, in these situations, there may well be additional acoustic system effects where inlet and outlet conditions at the fan are less than ideal.
The enveloping surface methods may be used for the determination of open inlet and/or open outlet sound power level of fans for standardized installation types.
An estimation (with increased uncertainty) of ducted sound power for fans too small, or otherwise inconvenient, for testing by the in-duct method described in ISO 5136 may also be obtained by the addition of end reflection corrections.
- Avant-proposiv
- Introductionv
-
1 Domaine d'application1
-
2 Références normatives1
-
3 Environnement acoustique et conduits2
-
4 Détermination de la surface de mesurage5
-
5 Méthode d'essai17
-
6 Essais acoustiques: détermination du niveau de puissance acoustique18
- Annexe A (normative) Détermination de l'indicateur d'environnement K220
- Bibliographie21
The Requirements department helps you quickly locate within the normative text:
- mandatory clauses to satisfy,
- non-essential but useful clauses to know, such as permissions and recommendations.
The identification of these types of clauses is based on the document “ISO / IEC Directives, Part 2 - Principles and rules of structure and drafting of ISO documents ”as well as on a constantly enriched list of verbal forms.
With Requirements, quickly access the main part of the normative text!

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.
Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!
Request your free, no-obligation live demo
I discover COBAZ