NF ISO 15529
Optics and photonics - Optical transfer function - Principles of measurement of modulation transfer function (MTF) of sampled imaging systems
ISO 15529:2010 specifies the principal MTFs associated with a sampled imaging system, together with related terms, and outlines a number of suitable techniques for measuring these MTFs. It also defines a measure for the “aliasing” related to imaging with such systems.ISO 15529:2010 is particularly relevant to electronic imaging devices such as digital still and video cameras and the detector arrays they embody.
ISO 15529:2010 specifies the principal MTFs associated with a sampled imaging system, together with related terms, and outlines a number of suitable techniques for measuring these MTFs. It also defines a measure for the “aliasing” related to imaging with such systems.
ISO 15529:2010 is particularly relevant to electronic imaging devices such as digital still and video cameras and the detector arrays they embody.
ISO 15529:2007 specifies the principal MTFs associated with a sampled imaging system, together with related terms and outlines a number of suitable techniques for measuring these MTFs. It also defines a measure for the “aliasing” related to imaging with such systems. ISO 15529:2007 is particularly relevant to electronic imaging devices such as digital still and video cameras and the detector arrays they embody.
- Avant-proposiv
-
1 Domaine d'application1
-
1 Références normatives1
-
3 Termes, définitions et symboles2
-
3.1 Termes et définitions2
-
3.2 Symboles4
-
4 Relations théoriques5
-
4.1 Transformée de Fourier de l'image de la fente objet (statique)5
-
4.2 Transformée de Fourier de la sortie d'une ouverture d'échantillonnage simple impliquant une fente objet explorée à travers l'ouverture7
-
4.3 Transformée de Fourier de la LSF moyenne impliquant différentes positions de la fente objet7
-
5 Méthodes de mesure des MTF associées aux systèmes de formation d'image8
-
5.1 Généralités8
-
5.2 Azimut d'essai9
-
5.3 Mesurage de la MTF du système, Tsys(r), d'un dispositif de formation d'image échantillonné ou d'un système complet10
-
5.4 Mesurage de la MTF de l'ouverture d'échantillonnage, Tap16
-
6 Méthode de mesure de la fonction de repliement du spectre, du rapport de repliement du spectre et du potentiel de repliement du spectre17
- Annexe A (informative) Théorie fondamentale18
- Annexe B (informative) Repliement du spectre dans les systèmes de formation d'image échantillonnés21
- Bibliographie26
The Requirements department helps you quickly locate within the normative text:
- mandatory clauses to satisfy,
- non-essential but useful clauses to know, such as permissions and recommendations.
The identification of these types of clauses is based on the document “ISO / IEC Directives, Part 2 - Principles and rules of structure and drafting of ISO documents ”as well as on a constantly enriched list of verbal forms.
With Requirements, quickly access the main part of the normative text!

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.
Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!
Request your free, no-obligation live demo
I discover COBAZ