IEC 60866:1987
Characteristics and calibration of hydrophones for operation in the frequency range 0.5 MHz to 15 MHz
Relates to hydrophones, employing piezoelectric sensor elements, designed to measure the pulsed and continuous-wave ultrasonic fields generated by ultrasonic medical equipment operating in the frequency range 0.5 MHz to 15 MHz. Covers the design and performance requirements of standard hydrophones and the data required to specify their characteristics, and defines a standard method for the measurement of the sensitivity of such hydrophones.Defines the performance characteristics that are required of hydrophones intended for use in a specified range of applications over the frequency band from 0.5 MHz to 15 MHz, particularly those associated with the measurement of pulsed and continuous-wave ultrasonic fields used in medical diagnosis. Establishes a scheme for the specification of the performance of these hydrophones. Describes a standardized procedure for their calibration.
Relates to hydrophones, employing piezoelectric sensor elements, designed to measure the pulsed and continuous-wave ultrasonic fields generated by ultrasonic medical equipment operating in the frequency range 0.5 MHz to 15 MHz. Covers the design and performance requirements of standard hydrophones and the data required to specify their characteristics, and defines a standard method for the measurement of the sensitivity of such hydrophones. Defines the performance characteristics that are required of hydrophones intended for use in a specified range of applications over the frequency band from 0.5 MHz to 15 MHz, particularly those associated with the measurement of pulsed and continuous-wave ultrasonic fields used in medical diagnosis. Establishes a scheme for the specification of the performance of these hydrophones. Describes a standardized procedure for their calibration.
IEC 62127-2:2007 specifies absolute hydrophone calibration methods and relative (comparative) hydrophone calibration methods. This standard is applicable to: - hydrophones used for measurements made in water and in the ultrasonic frequency range up to 40 MHz; - hydrophones employing circular piezoelectric sensor elements, designed to measure the pulsed wave and continuous wave ultrasonic fields generated by ultrasonic equipment; - and hydrophones with or without a hydrophone pre-amplifier. IEC 62127-1, IEC 62127-2 and IEC 62127-3 are being published simultaneously. Together these cancel and replace IEC 60866:1987, IEC 61101:1991, IEC 61102:1991, IEC 61220:1993 and IEC 62092:2001. The contents of the corrigendum of August 2008 have been included in this copy. The French version of this standard has not been voted upon.
IEC 62127-1:2007 specifies methods of use of calibrated hydrophones for the measurement in liquids of acoustic fields generated by ultrasonic medical equipment operating in the frequency range up to 40 MHz. The objectives of this standard are: - to define a group of acoustic parameters that can be measured on a physically sound basis; - to define a second group of parameters that can be derived under certain assumptions from these measurements, and called derived intensity parameters; - to define a measurement procedure that may be used for the determination of acoustic pressure parameters; - to define the conditions under which the measurements of acoustic parameters can be made in the frequency range up to 40 MHz using calibrated hydrophones; - and to define procedures for correcting, for limitations caused by the use of hydrophones with finite bandwidth and finite active element size. IEC 62127-1, IEC 62127-2 and IEC 62127-3 are being published simultaneously. Together these cancel and replace IEC 60866:1987, IEC 61101:1991, IEC 61102:1991, IEC 61220:1993 and IEC 62092:2001. The contents of the corrigendum of August 2008 have been included in this copy. The French version of this standard has not been voted upon.
IEC 62127-3:2007 specifies relevant hydrophone characteristics. This standard is applicable to hydrophones employing piezoelectric sensor elements, designed to measure the pulsed and continuous wave ultrasonic fields generated by ultrasonic equipment; hydrophones used for measurements made in water; and hydrophones with or without an associated pre-amplifier. IEC 62127-1, IEC 62127-2 and IEC 62127-3 are being published simultaneously. Together these cancel and replace IEC 60866:1987, IEC 61101:1991, IEC 61102:1991, IEC 61220:1993 and IEC 62092:2001. The French version of this standard has not been voted upon.