IEC 62127-3:2007

IEC 62127-3:2007

August 2007
International standard Cancelled

Ultrasonics - Hydrophones - Part 3: Properties of hydrophones for ultrasonic fields up to 40 MHz

IEC 62127-3:2007 specifies relevant hydrophone characteristics. This standard is applicable to hydrophones employing piezoelectric sensor elements, designed to measure the pulsed and continuous wave ultrasonic fields generated by ultrasonic equipment; hydrophones used for measurements made in water; and hydrophones with or without an associated pre-amplifier. IEC 62127-1, IEC 62127-2 and IEC 62127-3 are being published simultaneously. Together these cancel and replace IEC 60866:1987, IEC 61101:1991, IEC 61102:1991, IEC 61220:1993 and IEC 62092:2001. The French version of this standard has not been voted upon.

Main informations

Collections

International IEC standards

Publication date

August 2007

Number of pages

21 p.

Reference

IEC 62127-3:2007

Print number

1 - 01/10/2007
Sumary
Ultrasonics - Hydrophones - Part 3: Properties of hydrophones for ultrasonic fields up to 40 MHz

IEC 62127-3:2007 specifies relevant hydrophone characteristics. This standard is applicable to hydrophones employing piezoelectric sensor elements, designed to measure the pulsed and continuous wave ultrasonic fields generated by ultrasonic equipment; hydrophones used for measurements made in water; and hydrophones with or without an associated pre-amplifier. IEC 62127-1, IEC 62127-2 and IEC 62127-3 are being published simultaneously. Together these cancel and replace IEC 60866:1987, IEC 61101:1991, IEC 61102:1991, IEC 61220:1993 and IEC 62092:2001. The French version of this standard has not been voted upon.
Replaced standards (6)
International standard Cancelled
Amendment 1 - Measurement and characterisation of ultrasonic fields using hydrophones in the frequency range 0.5 MHz to 15 MHz

Defines alternative procedures for the measurement of acoustic pressure and derived intensity parameters for the sound fields generated by single ultrasonic transducers which have cylindrical or spherical active elements and defines additional acoustical terms.

IEC 62092:2001
August 2001
International standard Cancelled
Ultrasonics - Hydrophones - Characteristics and calibration in the frequency range from 15 MHz to 40 MHz

Applies to - hydrophones employing piezoelectric sensor elements, designed to measure the pulsed and continuous-wave ultrasonic fields generated by ultrasonic equipment; - hydrophones used for measurements made in water and in the frequency range between 15 MHz and 40 MHz; - hydrophones with or without an integral amplifier; - hydrophones with a circular piezoelectrically active element. Specifies - relevant hydrophone characteristics; - methods of determining directional response and hydrophone sensitivity based on relative or comparative measurements; and describes - absolute hydrophone calibration methods. Recommendations and references to accepted literature are made for the various relative and absolute calibration methods in the frequency range covered by this International Standard.

IEC 61101:1991
December 1991
International standard Cancelled
The absolute calibration of hydrophones using the planar scanning technique in the frequency range 0.5 MHz to 15 MHz

Specifies a method of absolute calibration of hydrophones based on the planar scanning technique in the frequency range 0,5 MHz to 15 MHz.

Technical specification Cancelled
Ultrasonics - Fields - Guidance for the measurement and characterization of ultrasonic fields generated by medical ultrasonic equipment using hydrophones in the frequency range 0,5 to 15 MHz

Provides guidance on the practical measurement of the acoustic output of various types of medical ultrasonic equipment. Contains also procedures for correcting limitations caused by the use of hydrophones with finite bandwidth and finite active element size.

IEC 61102:1991
November 1991
International standard Cancelled
Measurement and characterisation of ultrasonic fields using hydrophones in the frequency range 0.5 MHz to 15 MHz

Specifies the methods of use of calibrated piezoelectric hydrophones for the measurement in liquids of acoustic fields generated by ultrasonic medical equipment operating in the frequency range 0,5 MHz to 15 MHz.

IEC 60866:1987
May 1987
International standard Cancelled
Characteristics and calibration of hydrophones for operation in the frequency range 0.5 MHz to 15 MHz

Relates to hydrophones, employing piezoelectric sensor elements, designed to measure the pulsed and continuous-wave ultrasonic fields generated by ultrasonic medical equipment operating in the frequency range 0.5 MHz to 15 MHz. Covers the design and performance requirements of standard hydrophones and the data required to specify their characteristics, and defines a standard method for the measurement of the sensitivity of such hydrophones. Defines the performance characteristics that are required of hydrophones intended for use in a specified range of applications over the frequency band from 0.5 MHz to 15 MHz, particularly those associated with the measurement of pulsed and continuous-wave ultrasonic fields used in medical diagnosis. Establishes a scheme for the specification of the performance of these hydrophones. Describes a standardized procedure for their calibration.

See more
Standard replaced by (1)
IEC 62127-3:2022
December 2022
International standard Current
Ultrasonics - Hydrophones - Part 3: Properties of hydrophones for ultrasonic fields

IEC 62127-3:2022 specifies relevant hydrophone characteristics. This document is applicable to: - hydrophones employing piezoelectric sensor elements, designed to measure the pulsed and continuous wave ultrasonic fields generated by ultrasonic equipment; - hydrophones used for measurements made in water; - hydrophones with or without an associated pre-amplifier. IEC 62127-3:2022 cancels and replaces the first edition published in 2007 and Amendment 1:2013. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition. a) The upper frequency limit of 40 MHz has been removed. b) Hydrophone sensitivity definitions have been changed to recognize sensitivities as complex-valued quantities. c) Procedures to determine the effective hydrophone size have been changed according to the rationale outlined in Annex B. d) Requirements on the frequencies for which the effective hydrophone size shall be provided have been changed to achieve practicality for increased frequency bands. e) The new Annex B and Annex C have been added. f) Annex A has been updated to reflect the changes of the normative parts.