IEC 60947-4-1:2018
Low-voltage switchgear and controlgear - Part 4-1: Contactors and motor-starters - Electromechanical contactors and motor-starters
IEC 60947-4-1:2018 is applicable to the following equipment:- electromechanical contactors and starters including motor protective switching device (MPSD);- actuators of contactor relays;- contacts dedicated exclusively to the coil circuit of this contactor or this contactor relay;- dedicated accessories (e.g. dedicated wiring, dedicated latch accessory);intended to be connected to distribution circuits, motors circuits and other load circuits, the rated voltage of which does not exceed 1 000 V AC or 1 500 V DC. This fourth edition cancels and replaces the third edition published in 2009 and its Amendment 1:2012. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:- Scope structure and exclusions- Editorial correction of notes and hanging paragraphs- Reference to IEC 62683-1- Motor protective switching device (MPSD) with its requirements- Safety aspects related to:- General aspects;- Limited energy circuits;- Electronic circuits;- Assessment procedure for electromechanical overload protection used in safety -applications (new Annex L)- Introduction of provisions covering the impact of higher locked rotor current to achieve high efficiency class- Mention of dedicated wiring accessories- Pickup power measurement- Alignment to IEC 60947-1:2007, IEC 60947-1:2007/AMD1:2010, and IEC 60947?1:2007/AMD2:2014- Direct current requirements for covering photovoltaic application (new Annex M)- Load monitoring indicators (new Annex O)- Short-circuit breaking tests of MPSD (new Annex P)- Co-ordination under short-circuit conditions between a MPSD and another short-circuit protective device associated in the same circuit (new Annex Q).The contents of the interpretation sheet of March 2020, the corrigendum 1 of April 2020 and the corrigendum 2 of April 2021 have been included in this copy.
IEC 60947-4-1:2018 is applicable to the following equipment:
- electromechanical contactors and starters including motor protective switching device (MPSD);
- actuators of contactor relays;
- contacts dedicated exclusively to the coil circuit of this contactor or this contactor relay;
- dedicated accessories (e.g. dedicated wiring, dedicated latch accessory);
intended to be connected to distribution circuits, motors circuits and other load circuits, the rated voltage of which does not exceed 1 000 V AC or 1 500 V DC. This fourth edition cancels and replaces the third edition published in 2009 and its Amendment 1:2012. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- Scope structure and exclusions
- Editorial correction of notes and hanging paragraphs
- Reference to IEC 62683-1
- Motor protective switching device (MPSD) with its requirements
- Safety aspects related to:
- General aspects;
- Limited energy circuits;
- Electronic circuits;
- Assessment procedure for electromechanical overload protection used in safety -applications (new Annex L)
- Introduction of provisions covering the impact of higher locked rotor current to achieve high efficiency class
- Mention of dedicated wiring accessories
- Pickup power measurement
- Alignment to IEC 60947-1:2007, IEC 60947-1:2007/AMD1:2010, and IEC 60947?1:2007/AMD2:2014
- Direct current requirements for covering photovoltaic application (new Annex M)
- Load monitoring indicators (new Annex O)
- Short-circuit breaking tests of MPSD (new Annex P)
- Co-ordination under short-circuit conditions between a MPSD and another short-circuit protective device associated in the same circuit (new Annex Q).
The contents of the interpretation sheet of March 2020, the corrigendum 1 of April 2020 and the corrigendum 2 of April 2021 have been included in this copy.
IEC 60947-4-1:2009 applies to the types of equipment whose main contacts are intended to be connected to circuits the rated voltage of which does not exceed 1 000 V a.c. or 1 500 V d.c. Starters and/or contactors dealt with in this standard are not normally designed to interrupt short-circuit currents. Therefore, suitable short-circuit protection forms part of the installation but not necessarily of the contactor or the starter. This third edition replaces the second edition published in 2000 and its Amendments 1 (2002) and 2 (2005). It is a technical revision. This edition includes the following significant technical changes with respect to the previous edition (2000) and its Amendments 1 (2002) and 2 (2005): - deletion of the test at -5 °C and +20 °C for thermal overload relays that are not compensated for ambient air temperature; - addition of conditions of the tests according to Annex Q of IEC 60947-1; - EMC tests: clarification of acceptance criteria and alignment with IEC 60947-1 for fast transient severity level; - Annex B, test for Icd: modification of the duration of the dielectric test voltage from 5 s to 60 s; - Annex B, electrical durability: improvement of the statistical aspects; - Annex H: clarification and introduction of new extended functions within electronic overload relays; - Annex K, procedure to determine data for electromechanical contactors used in functional safety applications: creation of this new annex. This standard shall be read in conjunction with IEC 60947-1, Low voltage switchgear and controlgear - Part 1: General rules. The provisions of the general rules are applicable to this standard, where specifically called for. This publication shall be read in conjunction with IEC 60947-1 :2007.
IEC 60947-4-1:2023 is applicable to the following equipment: - electromechanical contactors and starters including motor protective switching devices (MPSD and IMPSD); - actuators of contactor relays; - contacts dedicated exclusively to the coil circuit of the contactor or the contactor relay; - dedicated accessories (e.g. dedicated wiring, dedicated latch accessory); intended to be connected to distribution circuits, motors circuits and other load circuits, the rated voltage of which does not exceed 1 000 V AC or 1 500 V DC. This fifth edition cancels and replaces the fourth edition published in 2018. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) objective in the scope; b) instantaneous only motor protective switching device IMPSD (3.5.33); c) kinds of equipment (5.2.1); d) methods of overload protection of motors (5.2.6); e) adoption of the AC-7d from IEC 61095:2023 (in 5.4.2); f) separately mounted overload relay of a starter (in 5.7.3 b)); g) starter and contactor suitable for use downstream to basic drive module (6.1.2 w)); h) reference to IEC TS 63058 for environmental aspects (in 6.4); i) wiring subject to movement (in 8.1.3); j) use of voltage transient limiting device (8.1.18); k) accessible parts subject to temperature limits (in 8.2.2.3); l) reference to Annex X of IEC 60947-1:2020 for the co-ordination of MPSD with SCPD (8.2.5.4); m) reference to IEC TR 63216 with different EMC environments (8.3.1); n) reference to IEC TR 63201 for the embedded software design (8.4); o) reference to IEC TS 63208 for cybersecurity aspects (8.5); p) update and completion of the measurement method of the power consumption of the electromagnet (9.3.3.2.1.2); q) update of Annex C including rational about AC-3e; r) determination of the critical load current for photovoltaic applications (M.8.7).