IEC 62056-31:1999

IEC 62056-31:1999

November 1999
International standard Cancelled

Electricity metering - Data exchange for meter reading, tariff and load control - Part 31: Use of local area networks on twisted pair with carrier signalling

Describes two new architectures for local bus data exchange with stations either energized or not. For non-energized stations, the bus supplies energy for data exchange. The first architecture completes the base protocol (IEC 61142) with remote transfer services. The second architecture allows operation of DLMS services using the same physical medium and the same physical layer. This complete compatibility guarantees the possibility of using IEC 61142 and IEC 62056-31 equipment on the same bus. This standard replaces IEC 61142 (1993).This publication is of high relevance for Smart Grid.

Main informations

Collections

International IEC standards

Publication date

November 1999

Number of pages

173 p.

Reference

IEC 62056-31:1999

Print number

1 - 19/06/2007
Sumary
Electricity metering - Data exchange for meter reading, tariff and load control - Part 31: Use of local area networks on twisted pair with carrier signalling

Describes two new architectures for local bus data exchange with stations either energized or not. For non-energized stations, the bus supplies energy for data exchange. The first architecture completes the base protocol (IEC 61142) with remote transfer services. The second architecture allows operation of DLMS services using the same physical medium and the same physical layer. This complete compatibility guarantees the possibility of using IEC 61142 and IEC 62056-31 equipment on the same bus. This standard replaces IEC 61142 (1993).

This publication is of high relevance for Smart Grid.
Standard replaced by (1)
IEC 62056-3-1:2013
August 2013
International standard Cancelled
Electricity metering data exchange - The DLMS/COSEM suite - Part 3-1: Use of local area networks on twisted pair with carrier signalling

IEC 62056-3-1:2013 describes three profiles for local bus data exchange with stations either energized or not. For non-energized stations, the bus supplies energy for data exchange. Three different profiles are supported: - base profile; - profile with DLMS; - profile with DLMS/COSEM. The three profiles use the same physical layer and they are fully compatible, meaning that devices implementing any of these profiles can be operated on the same bus. The transmission medium is twisted pair using carrier signalling and it is known as the Euridis Bus. This first edition cancels and replaces the first edition of IEC 62056-31, issued in 1999, and constitutes a technical revision. The main technical changes are: - addition of a profile which makes use of the IEC 62056 DLMS/COSEM Application layer and COSEM object model, - review of the data link layer which is split into two parts: a pure Data Link layer; a "Support Manager" entity managing the communication media; - ability to negotiate the communication speed, bringing baud rate up to 9 600 bauds.