IEC 62056-3-1:2013
Electricity metering data exchange - The DLMS/COSEM suite - Part 3-1: Use of local area networks on twisted pair with carrier signalling
IEC 62056-3-1:2013 describes three profiles for local bus data exchange with stations either energized or not. For non-energized stations, the bus supplies energy for data exchange. Three different profiles are supported:- base profile;- profile with DLMS;- profile with DLMS/COSEM. The three profiles use the same physical layer and they are fully compatible, meaning that devices implementing any of these profiles can be operated on the same bus. The transmission medium is twisted pair using carrier signalling and it is known as the Euridis Bus. This first edition cancels and replaces the first edition of IEC 62056-31, issued in 1999, and constitutes a technical revision. The main technical changes are:- addition of a profile which makes use of the IEC 62056 DLMS/COSEM Application layer and COSEM object model,- review of the data link layer which is split into two parts: a pure Data Link layer; a "Support Manager" entity managing the communication media;- ability to negotiate the communication speed, bringing baud rate up to 9 600 bauds.
IEC 62056-3-1:2013 describes three profiles for local bus data exchange with stations either energized or not. For non-energized stations, the bus supplies energy for data exchange. Three different profiles are supported:
- base profile;
- profile with DLMS;
- profile with DLMS/COSEM. The three profiles use the same physical layer and they are fully compatible, meaning that devices implementing any of these profiles can be operated on the same bus. The transmission medium is twisted pair using carrier signalling and it is known as the Euridis Bus. This first edition cancels and replaces the first edition of IEC 62056-31, issued in 1999, and constitutes a technical revision. The main technical changes are:
- addition of a profile which makes use of the IEC 62056 DLMS/COSEM Application layer and COSEM object model,
- review of the data link layer which is split into two parts: a pure Data Link layer; a "Support Manager" entity managing the communication media;
- ability to negotiate the communication speed, bringing baud rate up to 9 600 bauds.
Describes two new architectures for local bus data exchange with stations either energized or not. For non-energized stations, the bus supplies energy for data exchange. The first architecture completes the base protocol (IEC 61142) with remote transfer services. The second architecture allows operation of DLMS services using the same physical medium and the same physical layer. This complete compatibility guarantees the possibility of using IEC 61142 and IEC 62056-31 equipment on the same bus. This standard replaces IEC 61142 (1993). This publication is of high relevance for Smart Grid.
IEC 62056-3-1:2021 describes two sets of profiles: the first set of profiles allows a bidirectional communication between a client and a server. This set of profiles is made of three profiles allowing local bus data exchange with stations either energized or not. For non-energized stations, the bus supplies energy for data exchange. Three different profiles are supported: ? base profile: this three-layer profile provides remote communication services; NOTE 1 This first profile was published in IEC 61142:1993 and became known as the Euridis standard. ? profile with DLMS: this profile allows using DLMS services as specified in IEC 61334 4 41; NOTE 2 This second profile was published in IEC 62056-31:1999. ? profile with DLMS/COSEM: this profile allows using the DLMS/COSEM Application layer and the COSEM object model as specified in IEC 62056 5 3 and in IEC 62056 6 2 respectively. The three profiles use the same physical layer and they are fully compatible, meaning that devices implementing any of these profiles can be operated on the same bus. The transmission medium is twisted pair using carrier signalling and it is known as the Euridis Bus. The second set of profiles allows unidirectional communication between a given Energy Metering device and a Customer Energy Management System. This second set is made up of three profiles. Subclause 4.2.1 to Clause 8 included specify the bidirectional communication using twisted pair signalling and Clause 9 to 9.5 the unidirectional communication using twisted pair signalling. This second edition cancels and replaces the first edition of IEC 62056-3-1, issued in 2013, and constitutes a technical revision. The main technical changes with regard to the previous edition are as follows: ? addition of a profile which makes use of the IEC 62056 DLMS/COSEM Application layer and COSEM object model; ? review of the data link layer which is split into two parts: ? a pure Data Link layer; ? a "Support Manager" entity managing the communication media; ? ability to negotiate the communication speed, bringing baud rate up to 9 600 bauds.
COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.
Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!
Request your free, no-obligation live demo
I discover COBAZ