IEC 62271-100:2001

IEC 62271-100:2001

May 2001
International standard Cancelled

High-voltage switchgear and controlgear - Part 100: High-voltage alternating-current circuit-breakers

Is applicable to a.c. circuit-breakers designed for indoor or outdoor installation and for operation at frequencies of 50 Hz and 60 Hz on systems having voltages above 1 000 V.

Main informations

Collections

International IEC standards

Publication date

May 2001

Number of pages

575 p.

Reference

IEC 62271-100:2001

Print number

1
Sumary
High-voltage switchgear and controlgear - Part 100: High-voltage alternating-current circuit-breakers

Is applicable to a.c. circuit-breakers designed for indoor or outdoor installation and for operation at frequencies of 50 Hz and 60 Hz on systems having voltages above 1 000 V.
Replaced standards (4)
International standard Cancelled
Amendment 2 - High-voltage alternating-current circuit-breakers

International standard Cancelled
Amendment 3 - High-voltage alternating-current circuit-breakers

Includes Amendment N° 1 and Amendment N° 2

IEC 60056:1987/AMD1:1992
December 1992
International standard Cancelled
Amendment 1 - High-voltage alternating-current circuit-breakers

IEC 60056:1987
March 1987
International standard Cancelled
High-voltage alternating-current circuit-breakers

Applies to a.c. circuit-breakers designed for indoor or outdoor installation and operation at frequencies up to and including 60 Hz on systems having voltages above 1 000 V. Applies only to three-pole circuit-breakers for use in three-phase systems and single-pole circuit-breakers for use in single-phase systems. Two-pole circuit-breakers for use in single-phase systems are subject to agreement between manufacturer and user. Also applies to the operating devices of circuit-breakers and their auxiliary equipment. However, circuit-breakers with a closing mechanism for dependent manual operation are not covered since a rated short-circuit-making current cannot be specified, and dependent manual operation may be objectionable because of safety considerations. Does not cover circuit-breakers intended for use on motive power units of electrical traction equipment, or circuit-breakers for use with overhead lines which include series capacitors. Replaces IEC 60056-1 to 60056-6.

See more
Standard replaced by (1)
IEC 62271-100:2008
April 2008
International standard Cancelled
High-voltage switchgear and controlgear - Part 100: Alternating current circuit-breakers

IEC 62271-100:2008 is applicable to a.c. circuit-breakers designed for indoor or outdoor installation and for operation at frequencies of 50 Hz and 60 Hz on systems having voltages above 1 000 V. It is only applicable to three-pole circuit-breakers for use in three-phase systems and single-pole circuit-breakers for use in single-phase systems. This second edition cancels and replaces the first edition published in 2001 and its amendments 1 (2002) and 2 (2006). It also cancels and replaces IEC 61633 and IEC 62271-308. The main changes with respect to the previous edition are listed below: - the introduction of harmonised (IEC and IEEE) TRV waveshapes for rated voltages of 100 kV and above (amendment 1 to the first edition); - the introduction of cable and line systems with their associated TRVs for rated voltages below 100 kV (amendment 2 to the first edition); - the inclusion of IEC 61633 and IEC 62271-308. This standard shall be read in conjunction with IEC 62271-1, first edition, published in 2007.

Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo

I discover COBAZ