IEC 62387:2012
Radiation protection instrumentation - Passive integrating dosimetry systems for personal and environmental monitoring of photon and beta radiation
IEC 62387:2012 applies to all kinds of passive dosimetry systems that are used for measuring the personal dose equivalent (for whole body dosimetry), the personal dose equivalent (for eye lens dosimetry), the personal dose equivalent (for both whole body and extremity dosimetry), the ambient dose equivalent (for environmental dosimetry), or the directional dose equivalent (for environmental dosimetry). This standard applies to dosimetry systems that measure external photon and/or beta radiation in the dose range between 0,01 mSv and 10 Sv and in wide energy ranges. The dosimetry systems usually use electronic devices for the data evaluation and thus are often computer controlled.
IEC 62387:2012 applies to all kinds of passive dosimetry systems that are used for measuring the personal dose equivalent (for whole body dosimetry), the personal dose equivalent (for eye lens dosimetry), the personal dose equivalent (for both whole body and extremity dosimetry), the ambient dose equivalent (for environmental dosimetry), or the directional dose equivalent (for environmental dosimetry). This standard applies to dosimetry systems that measure external photon and/or beta radiation in the dose range between 0,01 mSv and 10 Sv and in wide energy ranges. The dosimetry systems usually use electronic devices for the data evaluation and thus are often computer controlled.
Applies to dosimetry systems that are capable of evaluating doses in the required quantity and unit (Sv) from readout signals in any quantity and unit. The only correction that may be applied to the evaluated dose (indicated value) is the one resulting from natural background radiation using extra dosemeters.
IEC 62387:2020 applies to all kinds of passive dosimetry systems that are used for measuring: - the personal dose equivalent Hp(10) (for individual whole body monitoring), - the personal dose equivalent Hp(3) (for individual eye lens monitoring), - the personal dose equivalent Hp(0,07) (for both individual whole body skin and local skin for extremity monitoring), - the ambient dose equivalent H*(10) (for workplace and environmental monitoring), - the directional dose equivalent H'(3) (for workplace and environmental monitoring), or - the directional dose equivalent H'(0,07) (for workplace and environmental monitoring). This document applies to dosimetry systems that measure external photon and/or beta radiation in the dose range between 0,01 mSv and 10 Sv and in the energy ranges given in Table 1. All the energy values are mean energies with respect to the fluence. The dosimetry systems usually use electronic devices for the data evaluation and thus are often computer controlled.
COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.
Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!
Request your free, no-obligation live demo
I discover COBAZ