IEC 62387:2020

IEC 62387:2020

January 2020
International standard Current

Radiation protection instrumentation - Dosimetry systems with integrating passive detectors for individual, workplace and environmental monitoring of photon and beta radiation

IEC 62387:2020 applies to all kinds of passive dosimetry systems that are used for measuring:- the personal dose equivalent Hp(10) (for individual whole body monitoring),- the personal dose equivalent Hp(3) (for individual eye lens monitoring),- the personal dose equivalent Hp(0,07) (for both individual whole body skin and local skin for extremity monitoring),- the ambient dose equivalent H*(10) (for workplace and environmental monitoring),- the directional dose equivalent H'(3) (for workplace and environmental monitoring), or- the directional dose equivalent H'(0,07) (for workplace and environmental monitoring).This document applies to dosimetry systems that measure external photon and/or beta radiation in the dose range between 0,01 mSv and 10 Sv and in the energy ranges given in Table 1. All the energy values are mean energies with respect to the fluence. The dosimetry systems usually use electronic devices for the data evaluation and thus are often computer controlled.

Main informations

Collections

International IEC standards

Publication date

January 2020

Number of pages

180 p.

Reference

IEC 62387:2020
Sumary
Radiation protection instrumentation - Dosimetry systems with integrating passive detectors for individual, workplace and environmental monitoring of photon and beta radiation

IEC 62387:2020 applies to all kinds of passive dosimetry systems that are used for measuring:
- the personal dose equivalent Hp(10) (for individual whole body monitoring),
- the personal dose equivalent Hp(3) (for individual eye lens monitoring),
- the personal dose equivalent Hp(0,07) (for both individual whole body skin and local skin for extremity monitoring),
- the ambient dose equivalent H*(10) (for workplace and environmental monitoring),
- the directional dose equivalent H'(3) (for workplace and environmental monitoring), or
- the directional dose equivalent H'(0,07) (for workplace and environmental monitoring).
This document applies to dosimetry systems that measure external photon and/or beta radiation in the dose range between 0,01 mSv and 10 Sv and in the energy ranges given in Table 1. All the energy values are mean energies with respect to the fluence. The dosimetry systems usually use electronic devices for the data evaluation and thus are often computer controlled.
Replaced standards (1)
IEC 62387:2012
December 2012
International standard Cancelled
Radiation protection instrumentation - Passive integrating dosimetry systems for personal and environmental monitoring of photon and beta radiation

IEC 62387:2012 applies to all kinds of passive dosimetry systems that are used for measuring the personal dose equivalent (for whole body dosimetry), the personal dose equivalent (for eye lens dosimetry), the personal dose equivalent (for both whole body and extremity dosimetry), the ambient dose equivalent (for environmental dosimetry), or the directional dose equivalent (for environmental dosimetry). This standard applies to dosimetry systems that measure external photon and/or beta radiation in the dose range between 0,01 mSv and 10 Sv and in wide energy ranges. The dosimetry systems usually use electronic devices for the data evaluation and thus are often computer controlled.

Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo

I discover COBAZ