IEC TS 60695-11-3:2000
IEC TS 60695-11-3:2000

IEC TS 60695-11-3:2000

March 2000
Technical specification Cancelled

Fire hazard testing - Part 11-3: Test flames - 500 W flames - Apparatus and confirmational test methods

Gives the detailed requirements for the production of a nominal 500 W, pre-mixed type test flame. the approximate overall height is 125 mm.Four methods are given: flame A and D may only be produced using methane, flame B may only be produced using propane and flame C may be produced using either methane or propane.Has the status of a basic safety publication in accordance with IEC Guide 104.

Main informations

Collections

International IEC standards

Thematics

QSE, Gestion des risques et SST, Sécurité

Publication date

March 2000

Number of pages

103 p.

Reference

IEC TS 60695-11-3:2000

ICS Codes

29.020   Electrical engineering in general
13.220.40   Ignitability and burning behaviour of materials and products

Print number

1
Sumary
Fire hazard testing - Part 11-3: Test flames - 500 W flames - Apparatus and confirmational test methods

Gives the detailed requirements for the production of a nominal 500 W, pre-mixed type test flame. the approximate overall height is 125 mm. Four methods are given: flame A and D may only be produced using methane, flame B may only be produced using propane and flame C may be produced using either methane or propane. Has the status of a basic safety publication in accordance with IEC Guide 104.
Replaced standards (1)
IEC TS 60695-2-4/2:1994
Technical specification Cancelled
Fire hazard testing - Part 2: Test methods - Section 4/sheet 2: 500 W nominal test flames and guidance

Gives the detailed requirements for the production of a nominal 500 W, pre-mixed type test flame. The approximate overall height is 125 mm. Two methods (A and B) are given: flame A based on methane; flame B based on propane. This publication has the status of a report Type 2. Has the status of a basic safety publication in accordance with IEC Guide 104.

Standard replaced by (1)
IEC TS 60695-11-3:2004
Technical specification Cancelled
Fire hazard testing - Part 11-3: Test flames - 500 W flames - Apparatus and confirmational test methods

Provides detailed requirements for the production of a 500 W nominal, pre-mixed type test flame. The approximate overall height is 125 mm. Two test flames are described: Method A may only be produced using methane whereas method C may be produced using either methane or propane. The main changes with respect to the previous edition are described below: - The introduction has been revised, - Test methods B and D have been withdrawn. Test methods A and C have been retained with their original letter designation, - Normative reference ISO 1337 has been withdrawn without a replacement by ISO/TC 26. The callout Cu-ETP UNS 11000 is the replacement for all references to ISO 1337. It is taken from ASTM B187-00 and describes high conductivity electrolytic copper, - A new Annex H has been added which provides access to equipment manufacturers and suppliers,- Alignment with other publications in the IEC 60695-11 series has been made, where appropriate. Has the status of a basic safety publication in accordance with IEC Guide 104.

Need to identify, monitor and decipher standards?