NF C74-340

NF C74-340

April 1985
Standard Cancelled

Electromedical equipment. Cardiac defibrillators and cardiac defibrillators. Monitors. Particular safety requirements.

Main informations

Collections

National standards and national normative documents

Publication date

April 1985

Number of pages

40 p.

Reference

NF C74-340

ICS Codes

11.040.60   Therapy equipment

Classification index

C74-340

Print number

1 - 01/06/1985

International kinship

IEC 60601-2-4:1983
Replaced standards (3)
NF C74-307
June 1970
Standard Cancelled
Electromedical equipment stationary defibrillators

NF C74-307/A1
October 1980
Standard Cancelled
Additif à la norme NF C 74-307, juin 1970.

NF C74-340
July 1975
Standard Cancelled
Electromedical equipment. First-aid defibrillators.

Standard replaced by (1)
NF EN 60601-2-4
February 2006
Standard Cancelled
Medical electrical equipment - Part 2-4 : particular requirements for the safety of cardiac defibrillators

Le présent document spécifie les exigences de sécurité relatives aux DEFIBRILLATEURS CARDIAQUES tels qu'ils sont définis en 2.1.101 et qui sont désignés dans la suite du texte sous le terme APPAREILS. Ce document entre dans le champ d'application de la Directive n° 93/42/CEE du 14/06/1993 relative aux dispositifs médicaux.

Table of contents
  • AVANT-PROPOS
    3
  • SECTION UN - GÉNÉRALITÉS
  • I Domaine d'application et objet
    4
  • 2 Terminologie et définitions
    4
  • 4 Prescriptions générales relatives aux essais
    6
  • 5 Classification
    6
  • 6 Identification, marquage et documentation
    6
  • 7 Puissance absorbée
    9
  • SECTION DEUX - RÈGLES DE SÉCURITÉ
  • SECTION TROIS - PROTECTION CONTRE LES RISQUES DE CHOCS ÉLECTRIQUES
  • 14 Prescriptions relatives à la classification
    9
  • 17 Isolation et IMPÉDANCES DE PROTECTION
    10
  • 19 COURANTS DE FUITE permanents et COURANT AUXILIAIRE PATIENT
    11
  • 20 Tension de tenue
    12
  • SECTION QUATRE - PROTECTION CONTRE LES RISQUES MÉCANIQUES
  • SECTION CINQ - PROTECTION CONTRE LES RISQUES DUS AUX RAYONNEMENTS NON DÉSIRÉS OU EXCESSIFS
  • SECTION SIX - PROTECTION CONTRE LES RISQUES D'EXPLOSIONS DANS LES LOCAUX A USAGE MÉDICAL
  • SECTION SEPT - PROTECTION CONTRE LES TEMPÉRATURES EXCESSIVES. LE FEU ET LES AUTRES RISQUES TELS QUE LES ERREURS HUMAINES
  • 42 Températures excessives
    15
  • 44 Débordements, écoulements. fuites, humidité, pénétration de liquides, nettoyage, stérilisation et désinfection
    15
  • 46 Erreurs humaines
    16
  • SECTION HUIT - PRÉCISION DES CARACTÉRISTIQUES DE FONCTIONNEMENT ET PROTECTION CONTRE LES PUISSANCES DÉLIVRÉES INCORRECTES
  • 50 Précision des caractéristiques de fonctionnement
    17
  • 51 Protection contre les caractéristiques de sortie incorrectes
    18
  • SECTION NEUF - CONDITIONS DE DÉFAUT, CAUSES DE SURÉCHAUFFEMENT
  • ET/OU DE DÉTÉRIORATION MÉCANIQUE; ESSAIS D'ENVIRONNEMENT SECTION DIX - RÈGLES DE CONSTRUCTION
  • 56 Composants et ensembles
    19
  • 57 PARTIES RELIÉES AU RÉSEAU, composants et montage
    21
  • SECTION 101 - PRESCRIPTIONS COMPLÉMENTAIRES RELATIVES A LA SÉCURITÉ
  • 101 Temps de charge
    21
  • 102 SOURCE ÉLECTRIQUE INTERNE
    21
  • 103 Endurance
    22
  • 104 SYNCHRONISEUR
    23
  • 105 Rétablissement du MONITEUR CARDIAQUE après une défibrillation
    23
  • 106 Perturbations du MONITEUR CARDIAQUE dues à la charge ou à la décharge interne
    24
  • FIGURES 101à 109
    25
  • ANNEXE B - Essais en cours de construction et/ou d'installation
    32
  • ANNEXE AA - Justifications
    33