NF EN ISO 10497
Testing of valves - Fire type-testing requirements
ISO 10497:2010 specifies fire type-testing requirements and a fire type-test method for confirming the pressure-containing capability of a valve under pressure during and after the fire test. It is not applicable to the testing requirements for valve actuators other than manually operated gear boxes or similar mechanisms when these form part of the normal valve assembly. Other types of valve actuators (e.g. electrical, pneumatic or hydraulic) can need special protection to operate in the environment considered in this valve test, and the fire testing of such actuators is outside the scope of ISO 10497:2010.
ISO 10497:2010 specifies fire type-testing requirements and a fire type-test method for confirming the pressure-containing capability of a valve under pressure during and after the fire test. It is not applicable to the testing requirements for valve actuators other than manually operated gear boxes or similar mechanisms when these form part of the normal valve assembly. Other types of valve actuators (e.g. electrical, pneumatic or hydraulic) can need special protection to operate in the environment considered in this valve test, and the fire testing of such actuators is outside the scope of ISO 10497:2010.
Le présent document prescrit les caractéristiques d'un essai type au feu et décrit une méthode d'essai type au feu permettant d'établir la capacité de tenue en pression d'un appareil de robinetterie sous pression pendant et après l'exécution de l'essai au feu. Le présent document ne traite pas des essais des actionneurs des appareils de robinetterie autres que ceux liés à l'appareil normalement assemblé (par exemple les réducteurs).
This document specifies fire type-testing requirements and a fire type-test method for soft- and metal-seated isolation valves with one or more obturators. It is not applicable to the testing requirements for valve actuators other than manually operated gearboxes or similar mechanisms when these form part of the normal valve assembly. Other types of valve actuators (e.g. electrical, pneumatic or hydraulic) can need special protection to operate in the environment considered in this valve test, and the fire testing of such actuators is outside the scope of this document. This document specifies the measurement and assessment criteria for: a) through-seat leakage; b) external leakage; c) cavity overpressure relief of double-seated valves; d) operability. This document specifies the rules whereby the fire-type testing qualification for a valve can be extended to untested sizes, pressure ratings and materials of construction of the same basic design type. Fire test reports of valves tested according to previous editions of this document are acceptable when submitted together with the full and compliant fire test report as per 6.7 of the edition under which it was tested. Any data missing as required from 6.7 within the fire test report are accepted or rejected at the purchaser’s discretion. NOTE For the purposes of this document, the terms “fire type-test” and “fire test” are synonymous.
- Avant-proposiv
- Introductionv
-
1 Domaine d'application1
-
2 Références normatives1
-
3 Termes et définitions1
-
4 Conditions d'essai3
-
4.1 Sens et conditions d'essai des appareils de robinetterie3
-
4.2 Système de limitation de la pression3
-
5 Méthode d'essai au feu3
-
5.1 Avertissement général3
-
5.2 Principe3
-
5.3 Appareillage4
-
5.4 Fluide d'essai5
-
5.5 Combustible d'essai5
-
5.6 Mode opératoire5
-
6 Performances11
-
6.1 Généralités11
-
6.2 Fuite à travers les sièges pendant la période d'exposition au feu11
-
6.3 Fuite externe pendant les périodes d'exposition au feu et de refroidissement11
-
6.4 Fuite à travers les sièges après refroidissement pour les essais à faible pression12
-
6.5 Manoeuvrabilité12
-
6.6 Fuite externe après essai de fonctionnement12
-
6.7 Rapport d'essai13
-
7 Qualification d'autres appareils de robinetterie par dimension et pression représentatives et matériaux de construction15
-
7.1 Généralités15
-
7.2 Matériaux de construction15
-
7.3 Qualification des appareils de robinetterie par diamètre nominal16
-
7.4 Qualification des appareils de robinetterie par pression nominale16
-
7.5 Marquage spécial16
- Bibliographie18
The Requirements department helps you quickly locate within the normative text:
- mandatory clauses to satisfy,
- non-essential but useful clauses to know, such as permissions and recommendations.
The identification of these types of clauses is based on the document “ISO / IEC Directives, Part 2 - Principles and rules of structure and drafting of ISO documents ”as well as on a constantly enriched list of verbal forms.
With Requirements, quickly access the main part of the normative text!

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.
Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!
Request your free, no-obligation live demo
I discover COBAZ