NF EN ISO 10848-4

NF EN ISO 10848-4

August 2013
Standard Cancelled

Acoustics - Laboratory measurement of the flanking transmission of airborne and impact sound between adjoining rooms - Part 4 : application to junctions with at least one heavy element

ISO 10848-4:2010 specifies laboratory measurements of normalized flanking level difference, normalized flanking impact sound pressure level or vibration reduction index of buildings where at least one of the elements that form the construction under test is not a light element. ISO 10848-4:2010 applies to T- or X-junctions.

View the extract
Main informations

Collections

National standards and national normative documents

Publication date

August 2013

Number of pages

17 p.

Reference

NF EN ISO 10848-4

ICS Codes

91.120.20   Acoustics in building. Sound insulation

Classification index

S31-097-4

Print number

1 - 22/07/2013

International kinship

European kinship

EN ISO 10848-4:2010
Sumary
Acoustics - Laboratory measurement of the flanking transmission of airborne and impact sound between adjoining rooms - Part 4 : application to junctions with at least one heavy element

ISO 10848-4:2010 specifies laboratory measurements of normalized flanking level difference, normalized flanking impact sound pressure level or vibration reduction index of buildings where at least one of the elements that form the construction under test is not a light element.

ISO 10848-4:2010 applies to T- or X-junctions.

Standard replaced by (1)
NF EN ISO 10848-4
December 2017
Standard Current
Acoustics - Laboratory and field measurement of flanking transmission for airborne, impact and building service equipment sound between adjoining rooms - Part 4 : Application to junctions with at least one Type A element

<p>ISO 10848 (all parts) specifies measurement methods to characterize the flanking transmission of one or several building components.</p> <p>ISO 10848-4:2017 specifies laboratory and field measurements of buildings where at least one of the elements that form the construction under test is a Type A element (defined in ISO 10848‑1).</p> <p>Laboratory measurements are used to quantify the performance of the junction with suppressed flanking transmission from the laboratory structure. Field measurements are used to characterize the in situ performance and it is not usually possible to suppress unwanted flanking transmission sufficiently; hence, the results are primarily representative of the performance of that junction when installed in that particular building structure.</p> <p>The measured quantities can be used to compare different products, or to express a requirement, or as input data for prediction methods, such as ISO 12354‑1 and ISO 12354‑2.</p>

ZOOM ON ... the Requirements department
To comply with a standard, you need to quickly understand its issues in order to determine its impact on your activity.

The Requirements department helps you quickly locate within the normative text:
- mandatory clauses to satisfy,
- non-essential but useful clauses to know, such as permissions and recommendations.

The identification of these types of clauses is based on the document “ISO / IEC Directives, Part 2 - Principles and rules of structure and drafting of ISO documents ”as well as on a constantly enriched list of verbal forms.

With Requirements, quickly access the main part of the normative text!

With Requirements, quickly access the main part of the normative text!
Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo