NF EN ISO 18086
NF EN ISO 18086

NF EN ISO 18086

December 2020
Standard Current

Corrosion of metals and alloys - Determination of AC corrosion - Protection criteria

This document specifies protection criteria for determining the AC corrosion risk of cathodically protected pipelines.It is applicable to buried cathodically protected pipelines that are influenced by AC traction systems and/or AC power lines.In the presence of AC interference, the protection criteria given in ISO 15589-1 are not sufficient to demonstrate that the steel is being protected against corrosion.This document provides limits, measurement procedures, mitigation measures, and information to deal with long-term AC interference for AC voltages at frequencies between 16,7 Hz and 60 Hz and the evaluation of AC corrosion likelihood.This document deals with the possibility of AC corrosion of metallic pipelines due to AC interferences caused by conductive, inductive or capacitive coupling with AC power systems and the maximum tolerable limits of these interference effects. It takes into account the fact that this is a long-term effect, which occurs during normal operating conditions of the AC power system.This document does not cover the safety issues associated with AC voltages on pipelines. These are covered in national standards and regulations (see, e.g., EN 50443).

Main informations

Collections

National standards and national normative documents

Publication date

December 2020

Number of pages

50 p.

Reference

NF EN ISO 18086

ICS Codes

77.060   Corrosion of metals

Classification index

A05-130

Print number

1

International kinship

ISO 18086:2019

European kinship

EN ISO 18086:2020
Sumary
Corrosion of metals and alloys - Determination of AC corrosion - Protection criteria

This document specifies protection criteria for determining the AC corrosion risk of cathodically protected pipelines.

It is applicable to buried cathodically protected pipelines that are influenced by AC traction systems and/or AC power lines.

In the presence of AC interference, the protection criteria given in ISO 15589-1 are not sufficient to demonstrate that the steel is being protected against corrosion.

This document provides limits, measurement procedures, mitigation measures, and information to deal with long-term AC interference for AC voltages at frequencies between 16,7 Hz and 60 Hz and the evaluation of AC corrosion likelihood.

This document deals with the possibility of AC corrosion of metallic pipelines due to AC interferences caused by conductive, inductive or capacitive coupling with AC power systems and the maximum tolerable limits of these interference effects. It takes into account the fact that this is a long-term effect, which occurs during normal operating conditions of the AC power system.

This document does not cover the safety issues associated with AC voltages on pipelines. These are covered in national standards and regulations (see, e.g., EN 50443).

Replaced standards (1)
NF EN ISO 18086
NF EN ISO 18086
October 2017
Standard Cancelled
Corrosion of metals and alloys - Determination of AC corrosion - Protection criteria (ISO 18086:2015)

Table of contents
  • 1 Domaine d'application
  • 2 Références normatives
  • 3 Termes et définitions
  • 4 Compétences du personnel en matière de protection cathodique
  • 5 Évaluation de l'influence due aux courants alternatifs
  • 6 Évaluation du risque de corrosion due aux courants alternatifs
  • 7 Niveaux d'influence acceptables
  • 8 Techniques de mesurage
  • 9 Mesures d'atténuation
  • 10 Mise en service
  • 11 Surveillance et maintenance
  • Annexe A Description simplifiée du phénomène de corrosion due aux courants alternatifs
  • Annexe B Témoins et sondes
  • Annexe C Oxydation coulométrique
  • Annexe D Influence des caractéristiques du sol sur le processus de corrosion due aux courants alternatifs
  • Annexe E Autres critères utilisés en présence d'une influence due aux courants alternatifs
  • Annexe F Paramètres à prendre en compte pour choisir un dispositif de découplage du courant continu
  • Annexe G Méthode de détermination de l'emplacement d'une électrode de référence par rapport à la terre lointaine
  • Annexe H Mesurage simultané sur un témoin des densités de courant à une fréquence élevée
  • Bibliographie
ZOOM ON ... the Requirements department

To comply with a standard, you need to quickly understand its issues in order to determine its impact on your activity.

The Requirements department helps you quickly locate within the normative text:

  • mandatory clauses to satisfy,
  • non-essential but useful clauses to know, such as permissions and recommendations.

The identification of these types of clauses is based on the document "ISO/IEC Directives, Part 2 - Principles and rules of structure and drafting of ISO documents" as well as on a constantly enriched list of verbal forms.

With Requirements, quickly access the main part of the normative text!


What is the Redline format?
New: UPSELL service
Need to identify, monitor and decipher standards?