NF EN ISO 3680

NF EN ISO 3680

September 2004
Standard Cancelled

Determination of flash/no flash - Rapid equilibrium closed cup method

ISO 3680:2004 specifies a method for the determination of the ability of paints (including water-borne paints), varnishes, paint binders, adhesives, solvents and petroleum and related products, when maintained at a selected test temperature within the range of - 30 degrees Celsius and 300 degrees Celsius, and under the conditions of test, to yield sufficient flammable vapour at this temperature to cause ignition on the application of a test flame in a standard manner. When used in conjunction with the flash detector (A.1.6), ISO 3680:2004 is also suitable to carry out a flash/no flash test on fatty acid methyl esters (FAME).

View the extract
Main informations

Collections

National standards and national normative documents

Publication date

September 2004

Number of pages

29 p.

Reference

NF EN ISO 3680

ICS Codes

75.080   Petroleum products in general
87.040   Paints and varnishes

Classification index

T60-617

Print number

1 - 04/10/2004

International kinship

European kinship

EN ISO 3680:2004
Sumary
Determination of flash/no flash - Rapid equilibrium closed cup method

ISO 3680:2004 specifies a method for the determination of the ability of paints (including water-borne paints), varnishes, paint binders, adhesives, solvents and petroleum and related products, when maintained at a selected test temperature within the range of - 30 degrees Celsius and 300 degrees Celsius, and under the conditions of test, to yield sufficient flammable vapour at this temperature to cause ignition on the application of a test flame in a standard manner. When used in conjunction with the flash detector (A.1.6), ISO 3680:2004 is also suitable to carry out a flash/no flash test on fatty acid methyl esters (FAME).

Standard replaced by (1)
NF EN ISO 3679
October 2015
Standard Cancelled
Determination of flash no-flash and flash point - Rapid equilibrium closed cup method

<p>ISO 3679:2015 specifies procedures for flash point tests, within the temperature range of -30 °C to 300 °C, for paints, including water-borne paints, varnishes, binders for paints and varnishes, adhesives, solvents, petroleum, and related products. The procedures are used to determine whether a product will or will not flash at a specified temperature (flash no-flash Procedure A) or the flash point of a sample (Procedure B). When used in conjunction with a flash detector, ISO 3679:2015 is also suitable to determine the flash point of fatty acid methyl esters (FAME).</p>

Table of contents
View the extract
  • Avant-propos
    iv
  • Introduction
    v
  • 1 Domaine d'application
    1
  • 2 Références normatives
    1
  • 3 Termes et définitions
    2
  • 4 Principe
    2
  • 5 Produits et réactifs
    2
  • 6 Appareillage
    2
  • 7 Préparation de l'appareillage
    3
  • 8 Échantillonnage
    4
  • 9 Traitement des échantillons
    4
  • 10 Mode opératoire
    5
  • 11 Calculs
    6
  • 12 Expression des résultats
    7
  • 13 Fidélité
    7
  • 14 Rapport d'essai
    8
  • Annexe A (normative) Appareillage de point d'éclair
    9
  • Annexe B (normative) Spécifications des thermomètres
    14
  • Annexe C (informative) Vérification de l'appareillage
    15
  • Annexe D (informative) Utilisation d'un insert de coupe d'essai
    18
  • Bibliographie
    19
Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo

I discover COBAZ