ISO 5764|IDF 108:2002 specifies a reference method for the determination of the freezing point of raw, pasteurized, UHT-treated or sterilized whole milk, partially skimmed milk and skimmed milk by using a thermistor cryoscope.The freezing point can be used for estimating the proportion of extraneous water in milk. Calculation of the amount of extraneous water is complicated by daily variation, seasonal variation, etc. and is not within the scope of ISO 5764¦IDF 108:2002.Results obtained from samples with a titratable acidity exceeding 20 ml of 0,1 mol/l sodium hydroxide solution per 10 g of non-fat solids will not be representative of the original milk.
ISO 5764|IDF 108:2002 specifies a reference method for the determination of the freezing point of raw, pasteurized, UHT-treated or sterilized whole milk, partially skimmed milk and skimmed milk by using a thermistor cryoscope.
The freezing point can be used for estimating the proportion of extraneous water in milk. Calculation of the amount of extraneous water is complicated by daily variation, seasonal variation, etc. and is not within the scope of ISO 5764¦IDF 108:2002.
Results obtained from samples with a titratable acidity exceeding 20 ml of 0,1 mol/l sodium hydroxide solution per 10 g of non-fat solids will not be representative of the original milk.
La présente norme fait partie d'un ensemble de normes applicables au lait et aux produits laitiers. Cet ensemble est composé de normes traitant de : l'échantillonnage des produits, méthodes d'essais physiques et chimiques, vocabulaire, contrôle microbiologique, verrerie de laboratoire spécifique. La présente norme traite plus particulièrement de la détermination du point de congélation du lait à l'aide d'un appareil (le cryoscope à thermistance).
- Avant-proposiv
- Introductionvi
-
1 Domaine d'application1
-
2 Références normatives1
-
3 Terme et définition1
-
4 Principe2
-
5 Réactifs2
-
6 Appareillage3
-
7 Échantillonnage5
-
8 Étalonnage du cryoscope à thermistance5
-
9 Préparation de l'échantillon pour essai6
-
9.1 Préparation6
-
9.2 Condition de l'échantillon6
-
10 Mode opératoire6
-
10.1 Vérifications préliminaires6
-
10.2 Vérification de routine de l'étalonnage6
-
10.3 Détermination6
-
11 Calcul et expression des résultats7
-
11.1 Calculs7
-
11.2 Expression des résultats7
-
12 Fidélité7
-
12.1 Essais interlaboratoires7
-
12.2 Répétabilité8
-
12.3 Reproductibilité8
-
13 Rapport d'essai8
- Annexe A (informative) Résultats de l'essai interlaboratoires9
- Annexe B (informative) Lignes directrices pour l'application de méthodes de routine au cryoscope à thermistance11
- Annexe C (informative) Ajustement du point de congélation utilisé comme référence pour le lait véritable15
- Bibliographie16
The Requirements department helps you quickly locate within the normative text:
- mandatory clauses to satisfy,
- non-essential but useful clauses to know, such as permissions and recommendations.
The identification of these types of clauses is based on the document “ISO / IEC Directives, Part 2 - Principles and rules of structure and drafting of ISO documents ”as well as on a constantly enriched list of verbal forms.
With Requirements, quickly access the main part of the normative text!

- With a single click, add a new language, the Requirements or Redline+ service and add one or more additional users.
- Whether you are in the process of acquiring a standard or it is already available in your personal space, the UPSELL service is available at every stage to help you understand it and implement it within your organization.
COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.
Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!
Request your free, no-obligation live demo
I discover COBAZ