NF ISO 11929-5

NF ISO 11929-5

December 2005
Standard Cancelled

Determination of the detection limit and decision threshold for ionizing radiation measurements - Part 5 : fundamentals and applications to counting measurements on filters during accumulation of radioactive materiel

ISO 11929-5:2004 specifies suitable statistical values which allow an assessment of the detection capabilities in ionizing radiation measurements and of the physical effect quantified by the measurand. For this purpose, Bayesian statistical methods are used to specify characteristic limits. ISO 11929-5:2004 deals with fundamentals and applications to counting measurements on filters during accumulation of radioactive material.

View the extract
Main informations

Collections

National standards and national normative documents

Publication date

December 2005

Number of pages

40 p.

Reference

NF ISO 11929-5

ICS Codes

17.240   Radiation measurements

Classification index

M60-200-5

Print number

1 - 05/01/2006

International kinship

ISO 11929-5:2005
Sumary
Determination of the detection limit and decision threshold for ionizing radiation measurements - Part 5 : fundamentals and applications to counting measurements on filters during accumulation of radioactive materiel

ISO 11929-5:2004 specifies suitable statistical values which allow an assessment of the detection capabilities in ionizing radiation measurements and of the physical effect quantified by the measurand. For this purpose, Bayesian statistical methods are used to specify characteristic limits.

ISO 11929-5:2004 deals with fundamentals and applications to counting measurements on filters during accumulation of radioactive material.

Standard replaced by (1)
NF ISO 11929
May 2010
Standard Cancelled
Determination of the characteristic limits (decision threshold, detection limit and limits of the confidence interval) for measurements of ionizing radiation - Fundamentals and application

<p>ISO 11929:2010 specifies a procedure, in the field of ionizing radiation metrology, for the calculation of the "decision threshold", the "detection limit" and the "limits of the confidence interval" for a non-negative ionizing radiation measurand, when counting measurements with preselection of time or counts are carried out, and the measurand results from a gross count rate and a background count rate as well as from further quantities on the basis of a model of the evaluation. In particular, the measurand can be the net count rate as the difference of the gross count rate and the background count rate, or the net activity of a sample. It can also be influenced by calibration of the measuring system, by sample treatment and by other factors.</p>

Table of contents
View the extract
  • Avant-propos
    iv
  • Introduction
    v
  • 1 Domaine d'application
    1
  • 2 Références normatives
    1
  • 3 Termes et définitions
    1
  • 4 Quantités et symboles
    3
  • 5 Valeurs statistiques et intervalle de confiance
    5
  • 5.1 Principes
    5
  • 5.2 Seuil de décision
    9
  • 5.3 Limite de détection
    10
  • 5.4 Limites de confiance
    10
  • 6 Application de la présente partie de l'ISO 11929
    11
  • 6.1 Valeurs spécifiques
    11
  • 6.2 Évaluation d'une méthode de mesure
    11
  • 6.3 Évaluation des résultats de mesure
    11
  • 6.4 Documentation
    11
  • 7 Valeurs de la fonction de distribution de la distribution normale standard
    12
  • Annexe A (informative) Exemple d'application de la présente partie de l'ISO 11929
    14
  • Bibliographie
    32
Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo

I discover COBAZ