NF ISO 13348
Industrial fans - Tolerances, methods of conversion and technical data presentation
ISO 13348:2007 specifies performance tolerances and the technical data presentation of industrial fans of all types. It does not apply for fans designed solely for low-volume air circulation, such as those used for household or similar purposes (ceiling and table fans, extractor fans, etc.). ISO 13348:2007 covers the four installation categories defined in ISO 5801: A, free inlet, free outlet; B, free inlet, ducted outlet; C, ducted inlet, free outlet; D, ducted inlet, ducted outlet.
ISO 13348:2007 specifies performance tolerances and the technical data presentation of industrial fans of all types. It does not apply for fans designed solely for low-volume air circulation, such as those used for household or similar purposes (ceiling and table fans, extractor fans, etc.).
ISO 13348:2007 covers the four installation categories defined in ISO 5801: A, free inlet, free outlet; B, free inlet, ducted outlet; C, ducted inlet, free outlet; D, ducted inlet, ducted outlet.
Le présent document spécifie les tolérances sur les performances et la présentation des caractéristiques techniques des ventilateurs industriels à l'exception des ventilateurs pour le brassage de l'air. Les ventilateurs accélérateurs font l'objet de la norme NF ISO 13350.
This document specifies performance tolerances and the technical data presentation for fans of all types. It does not apply for fans designed solely for low-volume air circulation, such as those used for household or similar purposes (ceiling and table fans, extractor fans, etc.). For jet fans, refer to ISO 13350. The upper limit of fan work per unit mass is normally 25 kJ/kg, corresponding to an increase of fan pressure of approximately 30 kPa for a mean density in the fan of 1,2 kg/m3. For higher values, agreement is to be reached between the supplier and the user. This document applies the five installation categories defined in ISO 5801: A free inlet, free outlet; B free inlet, ducted outlet; C ducted inlet, free outlet; D ducted inlet, ducted outlet; E free inlet and free outlet without a partition. The performance of a fan can vary considerably with the installation category it is operating within. Therefore, these categories form an important part of the definition of the fan?s technical data presentation. NOTE International acceptance of the five installation categories provides the opportunity to base a contract on the most appropriate fan category for the end user and the system designer. Correspondingly, the likelihood of the fan providing the agreed performance, without compromise or concession, is enhanced. The efficiency scaling procedures described in 8.1.5 apply to centrifugal fans and axial fans within the specific speed ranges shown in Table 4. To date, there is no experimental data to confirm how they apply to mixed flow fans, having specific speeds in between. Category E fans are treated in Clause 7.
- Avant-proposiv
- Introductionv
-
1 Domaine d'application1
-
2 Références normatives1
-
3 Termes et définitions2
-
4 Symboles et unités6
-
5 Tolérances sur les performances pour les ventilateurs de série8
-
5.1 Informations à fournir par l'acheteur8
-
5.2 Informations à fournir par le fournisseur9
-
5.3 Tolérances10
-
5.4 Arrangements commerciaux11
-
5.5 Essais contractuels11
-
6 Tolérances sur les performances pour les ventilateurs de série dans les protocoles d'évaluation certifiés23
-
6.1 Généralités23
-
6.2 Lois des ventilateurs23
-
6.3 Essais de contrôle24
-
6.4 Tolérances sur les performances aérauliques24
-
6.5 Tolérances acoustiques28
-
7 Méthodes de conversion28
-
7.1 Conversion des performances aérauliques expérimentales28
-
7.2 Conversion des résultats d'essais de puissance acoustique35
-
8 Présentation des données techniques43
-
8.1 Généralités43
-
8.2 Informations essentielles43
-
8.3 Diagramme de performance du ventilateur44
-
8.4 Informations complémentaires46
- Annexe A (normative) Documentation49
- Annexe B (normative) Marquage50
- Annexe C (informative) Résistance du système en fonction du débit51
- Bibliographie54
The Requirements department helps you quickly locate within the normative text:
- mandatory clauses to satisfy,
- non-essential but useful clauses to know, such as permissions and recommendations.
The identification of these types of clauses is based on the document “ISO / IEC Directives, Part 2 - Principles and rules of structure and drafting of ISO documents ”as well as on a constantly enriched list of verbal forms.
With Requirements, quickly access the main part of the normative text!

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.
Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!
Request your free, no-obligation live demo
I discover COBAZ